6c. Squeeze the bulb on the hydrometer, then
insert the hose into the cell.
6d. Release the bulb, drawing electrolyte into
the hydrometer to the fill line.
IMPORTANT:
Hold the hydrometer straight up
and down when drawing up the electrolyte. The
float needs to float free, not rubbing against the
sides of the hydrometer.
6e. Write down the specific gravity of each cell.
6f. The readings must be corrected for the
temperature of the electrolyte.
The hydrometer manufacture should list
the temperature the float is calibrated to.
Most are calibrated to 80
o
. To correct the
reading, add .004 to the reading for every
10
o
Above the calibrated temperature or
subtract .004 for every 10
o
below the cali-
brated temperature.
6g. Compare the reading to the chart.
IMPORTANT:
To prevent damage to the charg-
ing system disconnect the battery to charge it.
NOTE:
If battery needs to be charged, let battery
sit for ten minutes to stabilize after charging.
apply a load to the battery for 15 seconds to
remove the surface charge. Then re-check the
battery.
Specific Gravity
Charge Condition
1.265
Fully Charged
1.225
75% Charged
1.190
50% Charged
1.155
25% Charged
1.12
Fully Discharged
Battery Testers:
There are four major ways to check a battery:
•
Electrolyte test using a
Specific Gravity
tester
to compare the density of the electrolyte in a
fully charged battery to the density of water
(water = 1.0 s.g.).
•
Electrolyte test using a
Refractometer
to check
the density of the electrolyte by measuring the
degree to which light waves bend when passing
through the electrolyte.
•
Load test
that checks the out-put of the battery
after the fully charged battery has done a certain
amount of work. Fixed load testers are com-
monly available. Variable load testers are not
generally found in automotive or outdoor power
equipment repair shops.
•
Capacitance
test that checks the condition of
the battery plate core, regardless of the level of
charge.
Testing the battery:
1.
Adjustable load testing
Adjustable load testing is used if an adjustable load
tester is available. Follow the procedures specified by
the manufacturer of the tester to connect to the battery.
1a. Disconnect the battery cables.
IMPORTANT:
Disconnect the negative cable
first to help prevent a shorting hazard.
1b. Measure the temperature of the electro-
lyte.
1c. Connect a voltmeter and the load tester to
the appropriate terminals.
1d. Hook an amp probe onto the ground lead
of the load tester.
NOTE:
A shunt can be used in place of the amp
probe, but a second voltmeter will be needed to
get a measurement from the shunt.
1e. Apply a load equal to 50% of the battery’s
rated CCA for 15 seconds.
Summary of Contents for Volunteer 4x4 Utility Vehicle
Page 2: ......
Page 4: ......
Page 12: ...Chapter 1 Introduction 8 ...
Page 66: ...Chapter 2 Drive System CVT and Transfer Case 62 ...
Page 78: ...Kohler Enclosed CVT Addendum 74 ...
Page 92: ...Caterpillar Enclosed CVT Addendum 88 ...
Page 126: ...Chapter 3 Drive System Drive Shafts and Differentials 122 ...
Page 278: ...Chapter 8 Caterpillar Engine and Related Systems 274 ...
Page 319: ...Chapter 9 Electrical 315 Electrical Schematic Engine Harness w Kohler engine ...
Page 321: ...Chapter 9 Electrical 317 Electrical Schematic Engine Harness w Caterpillar engine 725 04341 ...
Page 322: ...Chapter 9 Electrical 318 ...
Page 327: ...5 ...
Page 328: ...6 ...