System Maintenance
38
/
55
6.1.5 Check the scanning platform side screw, worknut lubrication and pitch cleanliness.
Regularly top up lubricating oil, such as worknut pitch worn off(loose pitch) , replace the
lead screw’s worknut.
6.1.6 Check the drum motor timing belt tightness and wear & tear conditions, if necessary, adjust the
timing belt tightness or replace the timing belt if found fatigue.
6.1.7 Check the linear servo system encoder strip cleanliness, remove or wipe dust or stains with dry
cotton cloth gently. Strictly prohibit the use of alcohol, acetone and other liquids while wiping the
encoder strip, as this will damage the encoder’s marks coating;
6.1.8 Check the stepping motors, timing belts and related sensorsfor any fatigue conditions or dust,
timely cleaning on these parts, replace parts if found defective of fatigue.