Consumables Parts and Spare Parts
43
/
55
No.
Error Message.
Handling suggestion
48
Tail clamp adjust failed.
Please clean air slot on drum or Contact engineer
49
Tail clamp position is over limit, please check.
Please clean air slot on drum or Contact engineer
50
Plate size is over limit (drum cannot be balanced!).
Please clean balance block sensor or Contact engineer
51
Vacuum pressure is not correct.
Check air pump filter
52
Tail clamp failed, please turn off and check.
Please clean air slot on drum or Contact engineer
53
Main board control process start failed.
Restart CTP and PC or Contact engineer
54
Autoloader control process start failed.
Restart autoloader or Contact engineer
55
Plate loading last time abnormal!
Check plate stack
56
Laser cannot be started!
Open laser adjust program or Contact engineer
57
Cannot connect to autoloader.
Check power supply and cable connection
58
Drum cannot stop!
Contact engineer
59
Already plate on drum.
Check if plate on drum or do #105 test command or contact
engineer
60
Cannot connect to device! Make sure device is
power on and USB cable is connected or contact
engineer!
Check power supply, USB connection and USB drive.
61
Cannot read parameter file information!
Check if parameter file is correct
62
Device ID validate failed.
Read device ID again or contact engineer
63
Temperature compensation is not completed
(overtime)!
Check platform focus compensation movement or contact
engineer.
64
Main control board data flow is abnormal.
Restart PC or Contact engineer
65
When start record process, data in main control
board memory is not ready!
Restart PC or Contact engineer
66
Cannot start record process, platform position limit
signal is not correct.
Check platform position limit sensor or Contact engineer
67
Cannot find this error code information.
Contact engineer
68
Image format is unknown.
Check if dongle is plugged in
69
File size ## * ## is over template setting, cannot
open this file.
Setup another template or adjust current one
70
Resolution is not same, as template setting, cannot
open this file!
Setup another template or adjust current one
71
Parameter is over limit!
Check parameter or Contact engineer
72
Software version is too old, cannot read parameter!
Please update software.
Update current software