29
/
55
operating action.
d)
Observe the plate on the Drum adsorption, if plate end not detach from Drum surface, you may
manually peel the plate end off from Drum surface, and gently drag the plate onto the platform
guide, press the
button, device will automatic unload the whole plate until the Head
Clamp position,
button light is flashing, and waiting to be pressed for next operating action.
e)
Press the
button, device’s Head Clamp open, plate must be removed before Head Clamp
closed back in 1 minute. Follow by plate stopper guide raise up, Drum repositions to the loading
position, this completes the unloading procedures and prepare for the next operations.