High Speed Dome Camera Introduction Manual
27
The dome system has 7 alarm inputs and 2 alarm output. (optional
function). When an alarm is received, an input signal to the dome triggers
the user defined action (such as presets, patterns, etc.), and at meantime
the alarm output signals is activated.
1. ALARM NO.:
Move the cursor to the ALARM NO. Press IRIS OPEN to
enter and move the joystick up and down to select the
alarm input no. (Channel 1 and Channel 2)
2. INPUT STATE
:
Set the alarm contact status. There are two input states,
OPEN and CLOSE.
z
OPEN
normally open
z
CLOSE normally close
3. ALARM MODE
z
OFF
Alarm function is deactivated.
z
ON
Alarm function is activated.
z
AUTO
AUTO Alarm function will be activated and
deactivated
between START TIME and STOP TIME.
4. ACTION: Set the alarm action:
z
NONE
(default) No action.
z
PRESET Dome goes to preset. (Default as Preset 1)
z
SCAN
Dome starts auto scan (Default as Auto Scan 1)
z
SEQ
Dome runs auto cruise (Default as Auto Cruise 1)
z
PATTERN Dome runs pattern (Default as Pattern 1)
5. ALARM OUT: Set the auxiliary to activate:
z
OFF
Not alarm output will be activated.
z
OUT1
An alarm action will close AUX 1 output..
z
OUT2
An alarm action will activate AUX2 output.
6. RESET TIME:
Set up time for the alarm output (such as an alarm buzzed) when is triggered by the
detector. .
7. START /STOP TIME:
Set up the time to start alarm and stop alarm ONLY under the AUTO mode under
ALARM MODE