background image

                                                                                                     

        High Speed Dome Camera Introduction Manual

 

15

z

 

Protocol Setup (SW2) 

Our IR speed dome supports two protocols including Pelco P and Pelco D. 

All of them supports baud rate of 9600bps

4800bps

2400bps. 

 

Set the No.1~4 dip switch for the protocol configuration. 

Protocol  SW2-1 SW2-2 SW2-3 SW2-4 

PELCO-P ON  OFF OFF OFF 

PELCO-D OFF  ON  OFF  OFF 

Reserved 

… … … … 

 

z

 

Baud Rate Setup (SW2) 

Set the No.5~6 dip switch for the baud rate configuration. 

Baud Rate 

SW2-5 

SW2-6 

9600 OFF 

OFF 

4800 ON 

OFF 

2400 OFF 

ON 

Reserved …  … 

 

1.  If you want to control using DVR or P/T controller, their protocol must be identical to camera. 

Otherwise, you can not control the camera. 

2.  If you changed camera protocol by changing DIP S/W, the change will be effective after you 

reboot the camera. 

 

z

 

Dome Address Setup (SW1) 

1.  ID number of camera is set using binary number. The example is shown bellow. 

 

 

 

 

PIN  1 2 3 4 5 6  7  8 

ID 

Value 1 2 4 8 16 32 64 128 

Ex)  ID=5 

ON 

OFF

ON 

OFF

OFF

OFF 

OFF 

OFF 

Ex) ID=10 

OFF

ON 

OFF

ON 

OFF

OFF 

OFF 

OFF 

 

2.  The range of ID is 1~255. Factory default of Camera ID is 1. 

3.  If you want to control a certain camera, you must match the camera ID with Cam ID setting of 

DVR or Controller. 

4.  Speed dome can change the ID address and baud rate via OSD menu. 

 

Summary of Contents for 15-CD52WI

Page 1: ...Installation and Operation Manual for High Speed Dome Camera VER V1 0 15 CD55TWAI 15 CD55TWA 15 CD52WI Please read the operation manual carefully before installing and using this unit ...

Page 2: ...ntended to alert the user to the presence of un insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons This exclamation point symbol is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance WARNING To prevent the r...

Page 3: ...nded by manufacturer 6 Power source This product should be operated only from the type of power source indicated on the marking label Precautions Operating z Before using make sure power supply and others are properly connected z While operating if any abnormal condition or malfunction is observed stop using the camera immediately and then contact your local dealer Handling z Do not disassemble or...

Page 4: ... Method Installation Dimensions 9 10 10 3 Dome Setting DIP Switch Setup Cabling Check points before operation Reserved Preset OSD Menu Functions 14 16 18 19 21 4 How to use OSD Menu Language System Information Display Setup IDLE Camera Motion Restart Factory Default 23 23 24 26 37 42 50 51 5 Specifications Specifications Optional Bracket 52 54 ...

Page 5: ...A z Pan 0 01 120o S Tilt 0 01o 120o S 15 CD52WI z Auto object track with zoom in out and motion detection 15 CD55TWAI z Timing actions for 7 days of programmable schedule z Built in Semi conductor heater digital temperature sensor z PWM cooling fan vari speed temperature control z Reserved network interface and space for network module z Pan Tilt accuracy 0 01o 256 preset positions z 8 cruising tr...

Page 6: ...nual target tracking Only for the auto tracking IR speed dome z Power Up Action This function enables to resume the last action executed before power down Most of actions such as Preset Pattern Swing and Group are available for this function but jog actions are not available to resume z Auto Flip When the camera tilts downward and goes just beyond the vertical position the camera will rotate 180 d...

Page 7: ...end commands over a long time the dome camera will return to its default functions which include the home place auto pan auto cruise and pattern z Dome Address Setup The dome supports up to 256 addresses and the dome will only response to the instructions given to its own address Please check the dip switch on the bottom of the dome for address setup z Manual Object Tracking The use can move the j...

Page 8: ... aiming to compensate the brightness of the dark object and adjust the background brightness to get a clear image 5Auto Manual White Balance Auto Manual WB adjust depending on the environment light changes 6 Day and Night Switch Only for Day Nigh Camera Speed dome camera can auto switch according to the environmental illumination changes 7OSD Setup Only for camera with menu Call upon preset No 95 ...

Page 9: ...d Dome Camera Introduction Manual 8 Product Accessories 15 CD55TWAI 15 CD55TWA 15 CD52WI z Accessories User s Manual Anti drop Rope Caution DC12V 4A power for 15 CD55TWA DC12V 5A power for 15 CD55TWAI 15 CD52WI ...

Page 10: ...se contact us for any help during the installation z Installation Space and Density Checkup Please make sure the space is big enough to install our dome And also ensure the density of the ceilings or walls to hold total weight of the dome and its accessories z Cables Preparation Please choose the proper cable according to the transmission distance The min requirement of coaxial BNC cable is listed...

Page 11: ...eed Dome Camera Introduction Manual 10 Installation Method The IR speed dome could be installed in wall mount and pendant mount Installation Dimensions Wall Mount 15 CD55TWAI 15 CD55TWA 15 CD52WI Drill Drawing ...

Page 12: ...High Speed Dome Camera Introduction Manual 11 Pendant Mount 15 CD55TWAI 15 CD55TWA 15 CD52WI Drill Drawing ...

Page 13: ...rocedures 1 Take out the bracket from the package as shown mark the installation hole positions on the wall referencing to the bottom of bracket 2 Drill the hole and install 4 pieces of M8 expansion bolt into the hole 3 Take out the IR speed dome and put the cables through the bracket Use M5 screws to fix the bracket and dome body 4 Use 4 pieces of M8 screw nuts with washer to fix the bracket on t...

Page 14: ... dome 1 Take out the bracket from the package as shown mark the installation hole positions on the ceiling referencing to the bottom of bracket 2 Drill the hole and install 4 pieces of M8 expansion bolt into the hole 3 Take out the IR speed dome and put the cables through the sockets on the bottom of the pendant bracket Use M5 screws to fix the bracket and dome body 4 Use screw nuts with washer to...

Page 15: ...d dome address Set the DIP switch inside the dome body The relative DIP switch site and connecting wires are diagramed below for reference DIP Switch Setup 15 CD52WI The dip switches are under the cover as following picture 15 CD55TWA 15 CD55TWAI The dip switches are under the flange as following picture SW1 Dip switch for the dome address SW2 Dip switch for the dome protocol ...

Page 16: ...t to control using DVR or P T controller their protocol must be identical to camera Otherwise you can not control the camera 2 If you changed camera protocol by changing DIP S W the change will be effective after you reboot the camera z Dome Address Setup SW1 1 ID number of camera is set using binary number The example is shown bellow PIN 1 2 3 4 5 6 7 8 ID Value 1 2 4 8 16 32 64 128 Ex ID 5 ON OF...

Page 17: ... Rated Power Input Voltage Range Current Consumption Model DC 12V DC 11V 13 V 5A 15 CD52WI 15 CD55TWAI DC 12V DC 11V 13 V 4A 15 CD55TWA z RS 485 Communication 1 For PTZ control connect this line to keyboard and DVR To control multiple cameras at the same time RS 485 communication lines of them is connected in parallel as shown below 2 Speed Dome OSD Menu support the distal 120R resistance of the o...

Page 18: ...s of alarm input NO or NC automatically Normal Open and Normal Close define as below Normal Open No contact between alarm input and common point Normal Close Keeping contact between alarm input and common point z Alarm output 15 CD55TWA 15 CD55TWAI Signal Description Alarm output 1 Alarm output port 1 Alarm output 2 Alarm output port 2 Speed dome can detect the status of alarm input automatically ...

Page 19: ...ler or DVR z Refer to the following table when using standard Pelco D protocol controller Go Preset Press Call input Preset number and press Enter Set Preset Press Preset input Preset number and press Enter Run Pattern Press Call input Pattern number and press Enter Set Pattern Please refer to the pattern setup turn to Pattern Setup z If controller or DVR has no pattern button or function use shor...

Page 20: ...ise 1 10 Call 96 Enter End the preset setting 11 Set 83 Enter Call qq Enter Set dwell time of cruising 12 Set 86 Enter Start the pattern setting Default as pattern 1 13 Call 96 Enter End the pattern setting 14 Call 80 Enter Call pp Enter Call 99 Enter Start the qq scanning pp Scanning 1 8 qq speed value 1 30 15 Call 80 Enter Call pp Enter Set 93 Enter Set right boundary of the pp scanning 16 Call ...

Page 21: ...us will show Normal if system Is running normally If error happens testing result will be shown in or X means normal and X means error Please check the according meaning as follows Serial NO 1 2 3 4 5 6 Meaning Dip Switch Temperature Sensor Storage Pan Tit Camera General Rules of Key Operation for Menu z The menu items surrounded with always has its sub menu z For aIl menu level to go into sub men...

Page 22: ...High Speed Dome Camera Introduction Manual 21 OSD MENU FUNCTIONS ...

Page 23: ...title version date time and temperature scale Display Setup Enable Disable of OSD display on Main Screen z Display Setup splay setup allows the user to define the way to display the dome titles on the monitor z Dome Setup Set all of the speed dome functions z Camera Set all of the camera functions z Motion Set the action of speed dome including Preset Scan Cruise etc z Prestart Reset z Factory Def...

Page 24: ...system information as required The system information includes Dome ID dome address baud rate protocol temperature voltage alarm info dome title version date time and temperature scale Use the following steps to display the System Information screens 1 Use the joystick to position the cursor along the SYSTEM INFORMATION 2 Press Iris Open The SYSTEM INFORMATION screen opens 3 Mover the joystick up ...

Page 25: ...ons include z OFF Title will not be displayed when activated z ON Title will be continuously displayed when activated z 2 SEC Title will be displayed for 2 seconds after activation z 5 SEC Title will be displayed for 5 seconds after activation z 10 SEC Title will be displayed for 5 seconds after activation Move the cursor by joystick to the one you need to set and press Iris Open the item Move the...

Page 26: ...er light of the environment will be when the IR LED on 3 IR LED POWER Here the use can choose the power mode covering NORMAL MATCH and USER z NORMAL Near IR LED will be turned on when wide angle and Far IR LED will be turned on when small angle z MATCH The Near and Far IR LED will be turned on and off automatically to match the zoom in and out z USER The user can manually adjust the Near and Far I...

Page 27: ...press IRIS to enter and select between STATIC and DYNAMIC 9 START STOP TIME Set up time for IR LED to open and close under TIMING of control mode IDLE IDLE setting means if there is no command for the dome for a period of time the dome will run the actions as defined 1 TIME Move the cursor to TIME and press IRIS OPEN to enter and move the joystick up and dome to select among 30 sec 1 min 5 min 10 ...

Page 28: ... function is deactivated z ON Alarm function is activated z AUTO AUTO Alarm function will be activated and deactivated between START TIME and STOP TIME 4 ACTION Set the alarm action z NONE default No action z PRESET Dome goes to preset Default as Preset 1 z SCAN Dome starts auto scan Default as Auto Scan 1 z SEQ Dome runs auto cruise Default as Auto Cruise 1 z PATTERN Dome runs pattern Default as ...

Page 29: ...IRIS OPEN to enter the setup of Mask Number of the privacy zone 2 ENABLE To enable or disable this privacy mask function 3 SET Move the cursor here and press IRIS OPEN to enter the mode of setting the privacy mask Move the joystick Left Right Up Down on the screen to set up the privacy zone and press IRIS OPEN to confirm 4 DELETE Move the cursor here and press IRIS OPEN to delete the current No of...

Page 30: ...right to choose the date position and move it up and dome to adjust the figures Press IRIS OPEN to confirm 2 TIME Move the cursor here and press IRIS OPEN to enter Move the joystick left and right to choose the time position and move it up and dome to adjust the figures Press IRIS OPEN to confirm 3 SAVE CANCEL Move the cursor to SAVE and press IRIS OPEN to save the settings Move the cursor to DELE...

Page 31: ...ot access any dome setting without entering a valid password 1 EDIT PASSWORD Move the cursor here and press IRIS OPEN to enter Please under the old password before set up the new password The initial password is 111111 2 ENABLE Move the cursor here and press IRIS OPEN to enter Move the joystick to select between ON and OFF The user need to enter the password when opening the OSD under the status o...

Page 32: ...ess IRIS OPEN to enter Move the joystick up and down to select the input method such as English Cap English Chinese Figures and Symbols 3 Mover the cursor to next line of CAP and press IRIS OPEN to enter the mode of character input The selected character will be shown in high brightness Move the joystick up down left right to choose the needed characters Press IRIS OPEN to move the selected charac...

Page 33: ...EN to confirm The number selected will be input on the upper line 2 Move the cursor to INPUT the bottom menu and press IRIS OPEN to enter the mode of setting soft address Move the joystick to position the cursor beside 0 1 2 3 4 5 6 7 8 9 and press IRIS OPEN to enter And move the joystick again to select numbers of dome soft address and press IRIS OPEN to confirm The number selected will be input ...

Page 34: ...troduction Manual 33 AUX The user can set up the auxiliary output to trigger other devices from an alarm or a controller Move the cursor to AUX and press IRIS OPEN to enter to select ON or OFF to enable or disable this function ...

Page 35: ...T LIMIT Move the cursor here and press IRIS OPEN to enter Now the user can mover the joystick to control the PAN movement of the dome to a defined position for the left limit Press IRIS OPEN to confirm 2 RIGHT LIMIT Move the cursor here and press IRIS OPEN to enter Now the user can mover the joystick to control the PAN movement of the dome to a defined position for the right limit Press IRIS OPEN ...

Page 36: ...ion of the dome speed the user can enter this menu to set up Move the cursor to DOME SPEED and press IRIS OPEN to enter Move the joystick to select the dome speed when doing the pan movement Move the cursor to BACK EXIT and press IRIS OPEN to run the command of BACK or EXIT ...

Page 37: ...n Move the cursor to POWER ON ACTION and press IRIS OPEN to enter the mode of setup z NONE default No action z PRESET Dome goes to preset Default as Preset 1 z SCAN Dome starts auto scan Default as Auto Scan 1 z SEQ Dome runs auto cruise Default as Auto Cruise 1 z PATTERN Dome runs pattern Default as Pattern 1 ...

Page 38: ...IRIS OPEN to enter the setup mode Move the joystick up and down to select the camera types Press IRIS OPEN to confirm 2 BAUDRATE Move the cursor here and press IRIS OPEN to enter the setup mode Move the joystick up and down to select the baud rate Press IRIS OPEN to confirm 3 PARITY Move the cursor here and press IRIS OPEN to enter the setup mode Move the joystick up and down to select the parity ...

Page 39: ... TEST The dome can do self diagnosis for the communications between keyboard and speed dome The test needs to match with our software VK200 If the self testing is successfully finished via the software the system will show up the testing results as left diagram ...

Page 40: ...ne preset scene to another 3 AUTO FLIP When the camera tilts downward and goes just beyond the vertical position the camera will rotate 180 degrees The user can press IRIS OPEN to enter and choose to turn on off this function 4 STOP TIME To set up the time that dome will stops after receiving the last command Options include 5 15 30 60 Sec 5 MENU OFF TIME To set up the time that OSD menu be off wh...

Page 41: ...DIGITAL ZOOM Move the cursor here and press IRIS OPEN to enter Setup the function to be ON or OFF 3 BACKLIGHT Move the cursor here and press IRIS OPEN to enter Setup the function to be ON or OFF 4 PICTURE FLIP To set up the Tilt flip for the dome Move the cursor here and press IRIS OPEN to enter Setup the function to be ON or OFF 5 FREEZE If turn on this function the screen image will be frozen un...

Page 42: ...BLUE GAIN Only can be adjusted whet WB set as manual 4 BIRGHT To set up the brightness of the image Move the cursor here and press IRIS OPEN to enter Move the joystick to adjust and press IRIS OPEN to confirm 5 EXPOSURE To set up the exposure mode of the camera Options include AUTO MANUAL SHUTTER PRIORITY IRIS PRIORITY and BRIGHT PRIORITY The use can select different mode according the different l...

Page 43: ...e cursor here and press IRIS OPEN to enter the setup of Preset Title Check the detailed above in DOME TITLE settings 3 SET Move the cursor here and press IRIS OPEN to enter Move the dome to a defined position as preset point and press IRIS OPEN to save the preset position 4 CALL Move the cursor here and press IRIS OPEN to call up the current preset 5 DELETE Move the cursor here and press IRIS OPEN...

Page 44: ...r the setup of SCAN Title Check the detailed above in DOME TITLE settings 3 LEFT LIMIT Move the cursor here and press IRIS OPEN to enter Move the dome to a defined position as left limit and press IRIS OPEN to save this left boundary 4 RIGHT LIMIT Move the cursor here and press IRIS OPEN to enter Move the dome to a defined position as right limit and press IRIS OPEN to save this right boundary 5 S...

Page 45: ...item NO move joystick up or down to select the Serial NO of the preset in a sequence There are up to 32 presets in each sequence z When the is on the item PRESET move the joystick up or down to select the preset NO that the user wants to add in the sequence z When the is on the INTERVAL move the joystick up or down to select the interval time between each preset z When the is on the last item move...

Page 46: ...select a pattern number 14 and press IRIS OPEN to confirm 2 TITLE Move the cursor here and press IRIS OPEN to enter the setup of Pattern Title Check the detailed above in DOME TITLE settings 3 SET Move the cursor here and press IRIS OPEN to enter Move the dome up down left right make the zoom in out and press IRIS OPEN to save the pattern tour 4 START Move the cursor here and press IRIS OPEN to st...

Page 47: ...select a zone number 1 8 and press IRIS OPEN to confirm 2 TITLE Move the cursor here and press IRIS OPEN to enter the setup of Zone Title Check the detailed above in DOME TITLE settings 3 LEFT LIMIT Move the cursor here and press IRIS OPEN to enter Move the dome to a defined position as left limit and press IRIS OPEN to save this left boundary 4 RIGHT LIMIT Move the cursor here and press IRIS OPEN...

Page 48: ...EN to confirm 4 MOTION To setup the motion that will be operated in this time segment The motion includes NONE PRESET 1 8 SCAN 1 4 SEQUENCE 1 4 and PATTERN 1 4 5 ON OFF Move the cursor here and press IRIS OPEN to enter to enable or disable this function Press IRIS OPEN to confirm 6 COPY The user could set up each 8 segment of 7 days separately or can copy the finished setting for one day to the cu...

Page 49: ...o enter the setup of AREA EDIT The screen will display frame with Serial No The user can move the frame to the top left conner of the wanted detecting area and press IRIS OPEN to confirm Then move the joystick to adjust the size of the detecting area and press IRIS OPEN to confirm z DELETE Move the cursor here and press IRIS OPEN to delete the current detecting area z SENSITIVITY Move the cursor h...

Page 50: ... object auto tracking will activate alarm aux output at the same time Press IRIS OPEN to enter to select ON or OFF 4 ZOOM MATCH Under the auto tracking model if turn on the function of ZOOM MATCH the dome will do zooming in and out during auto tracking to keep the right proportion between the object and background Move the cursor there and press the IRIS OPEN to enter And move the joystick to sele...

Page 51: ...mera Introduction Manual 50 RESTART The dome allows the user to reset its settings remotely under this menu Move the cursor here and press IRIS OPEN to enter Select OK or CANCEL to continue the reset or cancel the reset ...

Page 52: ...ion Manual 51 FACTORY DEFAULTS FACTORY DEFAULTS will allow the user to recover all the setting to factory default setting Move the cursor here and press IRIS OPEN to enter Select OK or CANCEL to continue the reset or cancel the reset ...

Page 53: ... Line FCB EX1020 SONY 550 TV Line Zoom SCM 2270 SAMSUNG x 27 Optical Zoom x 16 Digital Zoom CZ36SCM COP x 36 Optical Zoom x 32 Digital Zoom SCM 2370 SAMSUNG x 37 Optical Zoom x 16 Digital Zoom FCB EX1020 SONY x 36 Optical Zoom x 12 Digital Zoom Focal length SCM 2270 SAMSUNG f 3 5mm 95mm CZ36SCM COP f 3 4mm 122 4mm SCM 2370 SAMSUNG f 3 5 mm 129 5 mm FCB EX1020 SONY f 3 4mm 122 4mm S N Ration 50 dB ...

Page 54: ...ach pattern 600 sec or 500 instructions Other Functions Auto flip Auto Parking Power Up Action etc Auto Track X X Yes Schedule Timing actions for 7 days of programmable schedule Communication RS 485 9600 4800 2400 Selectable or change from OSD menu Protocol Pelco D Pelco P Auto identify Privacy Zone 8 Zone Alarm Input X 7 Input 7 Input Alarm Output X 2 Output 2 Output OSD Menu PTZ information etc ...

Page 55: ...High Speed Dome Camera Introduction Manual 54 OPTIONAL BRACKET Ceiling Bracket CD03BU1 Inside Corner Bracket CD06BH Pole Bracket CD04BH Outside Corner Bracket CD05BH V 20140115 ...

Reviews: