High Speed Dome Camera Introduction Manual
15
z
Protocol Setup (SW2)
Our IR speed dome supports two protocols including Pelco P and Pelco D.
All of them supports baud rate of 9600bps
、
4800bps
、
2400bps.
Set the No.1~4 dip switch for the protocol configuration.
Protocol SW2-1 SW2-2 SW2-3 SW2-4
PELCO-P ON OFF OFF OFF
PELCO-D OFF ON OFF OFF
Reserved
… … … …
z
Baud Rate Setup (SW2)
Set the No.5~6 dip switch for the baud rate configuration.
Baud Rate
SW2-5
SW2-6
9600 OFF
OFF
4800 ON
OFF
2400 OFF
ON
Reserved … …
1. If you want to control using DVR or P/T controller, their protocol must be identical to camera.
Otherwise, you can not control the camera.
2. If you changed camera protocol by changing DIP S/W, the change will be effective after you
reboot the camera.
z
Dome Address Setup (SW1)
1. ID number of camera is set using binary number. The example is shown bellow.
PIN 1 2 3 4 5 6 7 8
ID
Value 1 2 4 8 16 32 64 128
Ex) ID=5
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
Ex) ID=10
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
2. The range of ID is 1~255. Factory default of Camera ID is 1.
3. If you want to control a certain camera, you must match the camera ID with Cam ID setting of
DVR or Controller.
4. Speed dome can change the ID address and baud rate via OSD menu.