You cannot operate 2 different types of controllable cameras simultaneously
via the Convision V6xx A.
5.6 The Key-Operated Switch
The key-operated switch is connected as shown in the figure.
Figure 6: Key-operated switch
The key-operated switch is used to
activate the alarm function. If a key-
operated switch is not connected, the
Convision V6xx A is automatically
activated. In this case, the red "Active"
LED will be lit.
Switch unlocked
Alarm function
activated
Switch locked
Alarm function
deactivated
5.7 Input and Output Connections
Connect only devices that have been designed for 12V to your
Convision V6xx A
Never use 230 Volts on your Convision V6xx!
5.7.1 Example: Input Connections
Alarm devices for various purposes can be connected to the six inputs. Please
observe that only 12 V devices may be connected to the inputs.
Since the inputs respond to low/high level changes, the components must be closed
in the idle state (NC type normally closed, "break contact").