6-16
Assembly Manual: Tube
Revised 12.2019
Fig 184 - Belt towards hopper
Fig 185 - Hopper eye bolts
Fig 186 - Discharge eye bolts
Fig 187 - Lift conveyor tube
6.4.2 Set Cable Tension:
Note:
Hold cable thimble when adjusting eye bolt
to keep cable straight.
IMPORTANT:
Tighten hopper eye bolts to secure hopper.
Set tension with discharge eye bolts.
Leave as much adjustment
capacity at the hopper end.
It can be easily reached
for future adjustments.
79. Tighten hopper eye bolts until five threads
go through the nut.
- Tighten the eye bolt lock nuts.
80. Loosen the lock nuts on the discharge end
eye bolts.
- Tighten nuts on eye bolts until they extend
1-1/2 inches (25 - 38 mm) out from the nut.
81. Raise the discharge end to check tube
straightness.
- Lift the conveyor at the Slide, with a winch.
The discharge end should rise above the
stand. Hopper remains sitting on the stand.