144
Epsilon EP-P Drive Reference Manual
www.controltechniques.com
Revision: A4
Endif
Loop
Jog.Stop
‘Stop jogging when the Jog+ input goes off.
Endif
If (DriveInput.4=ON) Then
‘Jog- if the Jog- input is on
Jog.0.MinusInitiate
‘Vel=0.1in/s
Do While (DriveInput.4=ON)
If (DriveInput.5=ON) Then
‘DriveInput.5 = “Jog Fast”
Jog.0.Vel = 1.0
‘in/s
Else
Jog.0.Vel = 0.1
‘in/s
Endif
Loop
Jog.Stop
‘Stop jogging when the Jog+ input goes off.
Endif
Loop
Playback Program (Program 2)
Home.0.Initiate
‘Sensor,Offset=0.000in,Vel=-10in/s
Do While (TRUE)
‘Repeat until the program is halted
Index.1.Initiate
‘Absolute,Posn=1.000in,Vel=5in/s
Wait For InPosn
DriveOutput.1=ON
‘Turn on DriveOutput.1 for 1 second
Wait For Time 1.000
‘seconds
DriveOutput.1=OFF
Index.2.Initiate
‘Absolute,Posn=20.000in,Vel=7in/s
Wait For InPosn
DriveOutput.1=ON
‘Turn on DriveOutput.1 for 1 second
Wait For Time 1.000
‘seconds
DriveOutput.1=OFF
Index.3.Initiate
‘Absolute,Posn=5.250in,Vel=10in/s
Wait For InPosn
DriveOutput.1=ON
‘Turn on DriveOutput.1 for 1 second
Wait For Time 1.000
‘seconds
DriveOutput.1=OFF
Loop
Summary of Contents for Epsilon EP-P
Page 2: ......
Page 124: ...110 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 200: ...186 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 218: ...204 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 238: ...224 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 244: ...230 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 247: ......