164
Epsilon EP-P Drive Reference Manual
www.controltechniques.com
Revision: A4
view. This instruction will wait until the graph buffer is full, then it exits into the looking for trigger state.
Any Command Complete
Home.AnyCommandComplete
This source is active when any home motion command is completed, if a stop is activated before the home has completed the function will not
be activated. Inactivated when a home command is executed.
Acceleration
Home.#.Accel
This parameter sets the average Acceleration rate used during the home, units are specified on the User Units page.
Accelerating
Home.#.Accelerating
Active during any acceleration while the specified home is in progress. Accelerating may turn off and on again based on the type of Home
selected. Accelerating will activate during the Home back off sensor motion.
At Velocity
Home.#.AtVel
This source is activated when the home velocity is reached when a the specified home is in progress. It will activate and deactivate base on the
home. Home At Velocity will not be activated during back off sensor portion of the home.
Calculated Offset
Home.#.CalculatedOffset
The Calculated offset is the distance travelled during the deceleration ramp from the home velocity to a stop. Calculated by PowerTools.
Command Complete
Home.#.CommandComplete
This source is active when the specified home command is completed, if a stop is activated before the home has completed the function or if
the Home Limit Distance has been exceeded it will not be activated. Inactive when a home command is executed.
Command In Progress
Home.#.CommandInProgress
This source is activated when the Home is initiated and remains active until all motion related to the Home has completed.
Deceleration
Home.#.Decel
The Deceleration ramp parameter is used during all the home moves specified in user units.
Decelerating
Home.#.Decelerating
This source is active during any deceleration while the specified home is in progress. Decelerating will turn off and on based on the type of
Home selected. Decelerating will activate during the Home back off sensor motion.
End of Home Position
Home.#.EndPosn
This parameter defines the drive position at the completion of a home. Typically used to define the machine coordinate home position.
Initiate
Home.#.Initiate
When activated, this destination will initiate the specified home. Home will not initiate if an index, jog, program, or stop is currently active.
Limit Distance
Home.#.LimitDist
This parameter places an upper limit on the incremental distance traveled during a home. If no home reference is found the motor will
decelerate to a stop at the limit distance and activate the Home.#.LimitDistHit event.
Summary of Contents for Epsilon EP-P
Page 2: ......
Page 124: ...110 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 200: ...186 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 218: ...204 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 238: ...224 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 244: ...230 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 247: ......