Torque Level Active
TorqueLevelActive
This source is used to indicate that the absolute value of the TorqueCommand is greater than or equal to the TorqueLevel
setting.
Torque Limit
TorqueLimit
This is the level to which the TorqueCommand will be limited when the TorqueLimitEnable input function is active.
Torque Limit Active
TorqueLimitActive
Active when the TorqueCommand is greater than the TorqueLimit and the TorqueLimitEnable input function is active.
Torque Limit
TorqueLimitEnable
This destination is used to enable the TorqueLimit. This is level sensitive.
Travel Limit Deceleration
TravelLimitDecel
This parameter defines the ramp used to decelerate the motor to a stop when any travel limit is activated.
Travel Limit Disable
TravelLimitDisable
TravelLimitDisable can be used from the Assignments view, or through a user program. It can be used to temporarily disable
the travel limit fault capability of the Epsilon EP-P drive. When TravelLimitDisable is activated, the travel limits (hardware or
software) are no longer valid. If disabled using a program, the travel limits will automatically be re-enabled when the program
ends, if they haven’t already been enabled. This feature is typically used when a machine must use one of its limit switches as
a home switch. The user disables the travel limits, then homes to the limit switch, and then re-enables the travel limit.
Travel Limit Minus Activate
TravelLimitMinusActivate
This destination is used to activate the travel limit minus fault. It should be assigned to the travel limit minus sensor. When it is
activated the drive will decelerate to a stop using the deceleration rate defined in the TravelLimitDecel parameter. This is level
sensitive.
Travel Limit Minus Active
TravelLimitMinusActive
This source is active when the TravelLimitMinusActivate is active.
Travel Limit Plus Activate
TravelLimitPlusActivate
This destination is used to activate the travel limit plus fault. It should be assigned to the travel limit plus sensor. When it is
activated the drive will decelerate to a stop using the deceleration rate defined in the TravelLimitDecel parameter. This is level
sensitive.
Travel Limit Plus Active
TravelLimitPlusActive
This source is active when the TravelLimitPlusActivate is active.
Decimal Places
TorqueUnits.Decimal
This parameter is the decimal point location for user torque units.
Summary of Contents for Epsilon EP-P
Page 2: ......
Page 124: ...110 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 200: ...186 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 218: ...204 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 238: ...224 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 244: ...230 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Page 247: ......