Operating Instructions
Insulated Conductor Rail System
SinglePowerLine Program 0813
BAL0813-0007-EN
www.conductix.com
translated document
page 94 of 108
DANGER!
Risk of injury due to entrapment!
An ensnarement and/or impact with moving conductor rails (slip ring) or current collectors connected
to the machine and other components must be prevented.
→
Cordon off the work area!
→
Use caution when working in the vicinity of the danger zone, in particular if protective devices
(covers, enclosures, control devices, etc.) have been removed or deactivated.
→
Wear personal protective equipment!
WARNING!
Risk of injury due to impacts, puncture wounds and cuts!
Hazard due to moving or falling parts during maintenance/servicing.
→
Wear personal protective equipment!
→
Cordon off the work area!
→
Use caution when working in the vicinity of, and particularly below, the conductor rail.
WARNING!
Fire hazard due to overload or sparking!
A fire hazard can occur due to overloads of the cable, electrical arcing or short-circuits.
→
Before recommissioning, ensure that all work has been completed and all components have been
properly installed.
→
Conduct electrical testing as prescribed.
→
Permissible current values must be observed.
→
Electrical fuses must be installed according to regulations.
→
Warn against misuse.
→
Do not store easily ignited materials near conductor rails.
→
Dimensioning is according to permissible system load capacity and provide for appropriate electrical
protective devices.
WARNING!
Risk of injury due to hot surfaces!
Components can get hot during operation.
→
Allow components to cool before servicing.
→
Wear personal protective equipment!
CAUTION!
The functioning and availability of the conductor rail system are dependent on the quality of the
contact surface!
Copper conductor rails are dependent on a lubricant-patina guideway that builds up during operation and
should not be removed (no sanding or brushing off). Observe the Maintenance Instruction WV0800-0004!