Operating Instructions
Insulated Conductor Rail System
SinglePowerLine Program 0813
BAL0813-0007-EN
www.conductix.com
translated document
page 72 of 108
Fig. 97: Mounted air gap 0813
NOTE!
A potential difference in the two conductor rails in the air gap can lead to spark formation
and electrical erosion in the rail during a current collector transfer.
For this reason, avoid potential constructive differences!
Use the QR code ("click" or "scan") to see our animation
Mounting the Air Gap Insulation
Section
6.4.3.10
Mount end caps
Required tools:
◼
Hexagon screwdriver, SW5
◼
Rubber mallet
End caps are used to close rail end points and for protection against contact with the rails.
Requirements:
The outer edges of the conductor rail must be deburred (see Fig. 46).
Distances:
End cap end to hanger clamp center: Min. 250 mm (up to 400 mm)
Work steps:
→
Tap the end cap (Pos. 1) onto the conductor rail end with careful and light mallet taps (Pos. 2) (see Fig. 98 and Fig. 99).