LBC-4000 L-Band Up/Down Converter System
Revision 6
Serial Interface Operation
8–18
MN-LBC-4000
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Retrieve
Configuration
Status
N/A
186 bytes,
alphanumeric
Query only.
Use “RCS” to return the configuration status for the unit.
Return the detailed configuration status for the unit:
FRE_A_xxxxx.xxx
Conv A frequency
ATT_A_xx.xx
Conv A attenuation
TX_A_yyy
Conv A mute state
SLP_A_x.x
Conv A slope adjustment
ONL_A_yyy
Conv A ONline/OFFline
FRE_B_xxxxx.xxx
Conv B frequency
ATT_B_xx.xx
Conv B attenuation
TX_B_yyy
Conv B mute state
SLP_B_x.x
Conv B slope adjustment
ONL_B_yyy
Conv B ONline/OFFline
RED_yyy
Conv Redundancy ON/OFF
AFR_yyy
Auto Fault Recovery ON/OFF
EXT_yyy
External Reference YES/NO
REF_xxx
Ref Osc Adjustment
REM_yyy
Remote Mode YES/NO
COMM_RS-xxx
Remote Interface RS-232/RS-485
ADD_xxxx
Remote Address 0001-9999
BR_xxxx
Remote Baud Rate
FMT_X-X-X
Remote Data Format
N/A
RCS_
RCS_F...X
Redundancy
Mode
RED_
3 bytes,
alphabetic
Command or Query.
Use “RED” to set or return the active redundancy mode.
Set or return in the form RED_yyy where:
yyy=ON (Redundancy is enabled)
yyy=OFF (Redundancy is disabled)
RED_
RED_
RED_