LBC-4000 L-Band Up/Down Converter System
Revision 6
Serial Interface Operation
8–15
MN-LBC-4000
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
List All Alarms
N/A
Varies
Query only.
Use “LAA” to return the list of stored alarms.
Return stored alarms in the form:
“xx yyyyyyyyyyy hh:mm:ss mm/dd/yy{cr}
“ “ “ “ {cr}
“ “ “ “ {cr}
xx yyyyyyyyyyy hh:mm:ss mm/dd/yy{cr}{lf}”
where:
xx=stored fault number
yyyyyyyyyyy=fault description
hh:mm:ss=fault time
mm/dd/yy=fault date
N/A
LAA_
LAA_ xx y...y
h...s m...y
Local or
Remote State
LRS_
1 byte, numeric,
0 to 3
Command or Query.
Use “LRS” to set or return the unit operating mode.
Set or return in the form LRS_x where:
x= 0 (Local)
x=1 (Serial Remote EIA-232/485)
x=2 (Ethernet Remote)
x=3 (ESerial Remote)
LRS_
LRS_
LRS_x
Retrieve Unit
MAC Address
N/A
12 bytes,
alphanumeric
Query only.
Returns the factory-assigned MAC address for the unit, in
hexadecimal.
Return in the form LRS_x where:
x= 0 (Local)
x=1 (Serial Remote EIA-232/485)
x=2 (Ethernet Remote)
x=3 (ESerial Remote)
Query Response Example: >0001/MAC_0006B00001C2{cr}{lf}
N/A
MAC_
MAC_aabbccd
deeff