INS_CNGE11FX3TX8MS[POE][HO] Rev. 11.6.17 PAGE 113
INSTRUCTION MANUAL
CNGE11FX3TX8MS[POE][HO]
TECH SUPPORT: 1.888.678.9427
Ethernet Protection Switch Configuration
This page allows the user to inspect and configure the current EPS Instance.
Object
Description
Instance Data
EPS ID
The ID of the EPS. Click on the ID of an EPS to enter the configuration page.
Domain
Port: This will create a EPS in the Port Domain. ‘W/P Flow’ is a Port.
Architecture
1+1: This will create a 1+1 EPS.
1:1: This will create a 1:1 EPS.
W Flow
The working flow for the EPS - See ‘Domain’.
P Flow
The protecting flow for the EPS - See ‘Domain’.
W SF MEP
The working Signal Fail reporting MEP.
P SF MEP
The protecting Signal Fail reporting MEP.
APS MEP
The APS PDU handling MEP.
Instance Configuration
Configured
Red: This EPS is only created and has not yet been configured - is not active.
Green: This EPS is configured - is active.
Protection Type
Unidirectional: EPS in the two ends can select traffic from different working/protecting flow. This
is only possible in case of 1+1.
Bidirectional: EPS in the two ends is selecting traffic from the same working/protecting flow. This
requires APS enabled. This is mandatory for 1:1
APS
The Automatic Protection Switching protocol can be enabled/disabled. This is mandatory for 1:1.
Revertive
The revertive switching to working flow can be enabled/disabled.
WTR Time
The Wait To Restore timing value to be used in revertive switching. Range is 1 to 720 seconds.
Hold Off Time
The timing value to be used to make persistent check on Signal Fail before switching. This is in
100 ms. and the max value is 100 (10 sec).
Instance Command