INS_CNGE11FX3TX8MS[POE][HO] Rev. 11.6.17 PAGE 249
INSTRUCTION MANUAL
CNGE11FX3TX8MS[POE][HO]
TECH SUPPORT: 1.888.678.9427
Quick Start
This section describes how to perform the following:
»
Log in and reset configuration to factory defaults
»
Set device hostname and admin user password
»
Set VLAN 1 IP address
»
Verify connectivity using ‘ping’
»
Display the current configuration and save it to flash storage
The following assumes the device is powered on and has a functional connection to a computer
using the serial console port on the device (115200 baud, no parity, 8 data bits, 1 stop bit, no flow
control).
The computer must be running a terminal emulator such as TeraTerm or PuTTY on Windows, or
Minicom on Linux.
Log In and Reset Configuration to Factory Default
Press Enter one or more times until the Username: prompt appears. Type admin and press Enter.
At the Password: prompt press Enter as there is no password required. This completes the login
sequence and displays the prompt, ‘#’.
Username: admin
Password: admin
#
At this point, the admin user is operating at the highest privilege level, level 15. This means full
control over the device and its configuration, and it is therefore possible to reset the configuration
to factory defaults. Type reload defaults and press Enter. When the prompt returns, the system has
reverted to factory defaults as follows.
# reload defaults
% Reloading defaults. Please stand by.
#