INS_CNGE11FX3TX8MS[POE][HO] Rev. 11.6.17 PAGE 46
INSTRUCTION MANUAL
CNGE11FX3TX8MS[POE][HO]
TECH SUPPORT: 1.888.678.9427
Object
Description
Trap Inform
Timeout
(seconds)
Indicates the SNMP trap inform timeout. The allowed range is 0 to 2147.
Trap Inform
Retry Times
Indicates the SNMP trap informs retry times. The allowed range is 0 to 255.
Trap Probe
Security Engine
ID
Indicates the SNMP trap probe security engine ID mode of operation. Possible values are:
Enabled: Enable SNMP trap probe security engine ID mode of operation.
Disabled: Disable SNMP trap probe security engine ID mode of operation.
Trap Security
Engine ID
Indicates the SNMP trap security engine ID. SNMPv3 sends traps and informs using USM for
authentication and privacy. A unique engine ID for these traps and informs is needed. When
“Trap Probe Security Engine ID” is enabled, the ID will be probed automatically. Otherwise, the ID
specified in this field is used. The string must contain an even number (in hexadecimal format) with
number of digits between 10 and 64, but all-zeros and all-’F’s are not allowed.
Trap Security
Name
Indicates the SNMP trap security name. SNMPv3 traps and informs using USM for authentication
and privacy. A unique security name is needed when traps and informs are enabled.
SNMP Trap
Event
System
Enable/disable that the Interface group's traps. Possible traps are:
Warm Start: Enable/disable Warm Start trap.
Cold Start: Enable/disable Cold Start trap.
Interface
Indicates that the Interface group's traps. Possible traps are: Indicates that the SNMP entity is
permitted to generate authentication failure traps. Possible modes are:
Link Up: Enable/disable Link up trap.
Link Down: Enable/disable Link down trap.
LLDP: Enable/disable LLDP trap.
Authentication
Indicates that the authentication group's traps. Possible traps are:
SNMP Authentication Fail : Enable/disable SNMP trap authentication failure trap.
Switch
Indicates that the Switch group's traps. Possible traps are:
STP: Enable/disable STP trap.
RMON: Enable/disable RMON trap.
Power Supply
Indicates that one of the power supply inputs has failed. Possible traps are:
PSFAIL: Enable/disable power supply fail trap.
Apply
Click to apply changes.
Reset
Click to revert to previous values.