Sea Tel 9711-56 IMA
Installation in 144” Radome
4-11
EAR Controlled - ECCN EAR99
33.
Route the C-Band feed
harness along the rigid
waveguide, around the
back/top of the reflector to
the right side where the ICU
and QOR Switch Box are
located.
34.
Connect the C-Band feed
harness to QOR switch box
J4 connector and tighten
the retainer screws.
35.
Connect the C-Band LNB
coax to S1A on the top of
the QOR switch box.
36.
Remove the 4 nylock nuts
from the bolts that pass up
through the wood and lower
isolation plate.
37.
Discard this hardware.
38.
Remove the 4 bolts in the U-
bracket that restrains the
Right side (shown) of the
cross-level beam.
39.
Remove the 4 bolts in the U-
bracket that restrains the
Left side (hidden in
foreground) of the cross-
level beam.
40.
Remove the foam padding
from both sides of the cross-
level beam.
41.
Discard this hardware.