TracVision R4/R5/L3/S3/C3
1
LNB Ground Isolation Instructions
TracVision
®
R4/R5/L3/S3/C3 LNB Ground
Isolation Instructions
The following instructions explain how to isolate the LNB from
ground in a TracVision R4/R5/L3/S3/C3 antenna that has a serial
number earlier than 060900472. You will simply install the four
ground-isolating nylon shoulder washers provided in the kit.
Tools Required
a.
Turn off the antenna and unplug all connected
receivers.
b.
Using a #2 Phillips screwdriver, remove the eight
#8-32 screws and washers securing the antenna’s
radome to the baseplate (see Figure 1). Carefully
remove the radome and set it aside in a safe place.
Figure 1 Removing the Radome
• #2 Phillips screwdriver
• 11/32" nut driver
• Drill and 1/4" bit
CAUTION
For your own safety, be sure to disconnect power from the
antenna and receiver(s) before performing this procedure.
#8-32 Screws
and Washers (x8)
54-0568 Rev. A