Sea Tel 9711-56 IMA
9711-56 IMA Technical Specifications
19-11
EAR Controlled - ECCN EAR99
19.4.3.
Multi-conductor Cables (Customer Furnished)
Due to the voltage losses across the multi-conductor cables, Sea Tel recommends the following wire
gauge for the AC & DC multi-conductor cables used in our standard pedestal installations:
Run Length
Conductor Size
up to 50 ft
20 AWG (0.8 mm)
up to 100 ft
18 AWG (1.0 mm)
up to 150 ft
16 AWG (1.3 mm)
up to 250 ft
14 AWG (1.6 mm)
Up to 350 ft
12 AWG (2.0 mm)
19.4.4.
AC Power Cable (Pedestal & RF Equipment)
Refer to Power Requirements specification for the ADE (above).
19.4.5.
AC Power Cable (Optional Marine Air Conditioner)
Voltage:
220 volts AC
Breaker Required
20 Amp
Full Load Amperage:
5.4 Amps
19.4.6.
Gyro Compass Interface Cable (Customer Furnished)
Type:
Multi-conductor, Shielded
Number of wires
4 Conductors for Step-By-Step Gyro, 5 Conductors for
Synchro
Wire Gauge:
see Multi-conductor Cables spec above
Insulation:
600 VAC