Installation in 168” Radome
Sea Tel 9711-56 IMA
5-20
EAR Controlled - ECCN EAR99
38.
Remove the 4 bolts in the U-
bracket that restrains the
Right side (shown) of the
cross-level beam.
39.
Remove the 4 bolts in the U-
bracket that restrains the
Left side (hidden in
foreground) of the cross-
level beam.
40.
Remove the foam padding
from both sides of the cross-
level beam.
41.
Discard this hardware.
42.
Pass lifting straps through
eyes in the top of the cross-
level beam. These starps
must be long enough to
clear the top of the
waveguides (as seen in the
next picture).
43.
Attach these 2 straps to a
crane or orther suitable
lifting mechanism.
44.
Slowly & carefully lift the
pedestal & reflector
assembly up, guiding the
spring and cables, up out of
the wooden frame.