O P E R A T I N G M A N U A L
8 0 0 . 7 4 9 . 2 7 6 1
w w w . c o a c h c o m m . c o m
9 0
Control Unit Specifications
Control Unit Specification
XCU-44
Hardwired Intercom Audio Channels (per CU) 8 (four 2-wire and four 4-wire)
Active Radio Packs (Normal Mode) (per CU)
18 (18 active Normal Mode Radio Packs requires use of 3 RTs.)
No. of Paired Radio Packs Supported (per CU) 256
USB Ports
(1) USB Type A; (1) Micro USB
Front Panel LCD Display
512 × 128 resolution
Stage Announce and GPO Closures
5 Relays via DA-15
X-Net Ports (supports 2 connections)
(2) RJ-45 for copper; (1) duplex LC for Single Mode Fiber
Sync In Ports (supports 1 connection)
(1) RJ-45 for copper; (1) duplex LC for Single Mode Fiber
2-Wire Intercom Connection
4 channels via XLR 3F
with XLR 3M loop (4 ports)
2-Wire Compatibility
Clear-Com, RTS, and AudioCom (Balanced)
4-Wire Intercom Connection
4 ports via RJ-45
Stage Announce Output
XLR 3M, nominal 12 dBu into 600 ohms, balanced, transformer isolated
AUX IN
1/4” (6.35 mm) 3 conductor jack, 17.5 dBu max in,
balanced, transformer isolated
AUX OUT
1/4” (6.35 mm) 3 conductor jack, 12 dBu into 600 ohms,
balanced, transformer isolated
LAN Port
(1) RJ-45
Power Input/Connector
100–240V ~ 50–60 Hz, 1.8A
Dimensions
1 RU, 19 in. × 1.73in. × 11.68 in. (48.3 cm × 4.4 cm × 29.7 cm) metal
enclosure
Weight
6.5 lbs (2.9 kg)
Operating Environment
-20° to 50° C (-4° to 122° F); 10% to 90% Humidity.
Maximum Line Length
Copper 330 ft. (100 m); Fiber 32,800 ft. (10,000 m)
Maximum Altitude
6,562 ft. (2,000 m)
RoHS Compliant
Yes