POWERDRIVE 3 – MODEL 26580
Test Procedures
2008-2011 Domestic Battery Charger Maintenance and Service Manual
Page 7-27
7
Relay
1. Disconnect AC cord from the wall outlet and DC plug from the vehicle receptacle.
2. Remove the charger cover.
3. Remove black wires (3 and 4) from contact terminals of the relay
(Figure 7-9, Page 7-11)
. Place conti-
nuity test probes on contact terminals of the relay. The tester should indicate no continuity. If tester indi-
cates continuity, the relay contacts have failed closed and the relay must be replaced.
4. Place continuity test probes on contact terminals of relay. With batteries connected, insert DC plug into
receptacle. The tester should indicate continuity. If tester does not indicate continuity, relay must be
replaced.
Ammeter
1. Disconnect AC cord from the wall outlet and DC plug from the vehicle receptacle.
2. Remove the charger cover.
3. Disconnect the white wire from the left ammeter terminal (as viewed from inside the charger).
4. Place the continuity tester clip on one of the ammeter posts.
5. Place the continuity test probe on the other ammeter post. The tester should indicate continuity. If the
tester does not indicate continuity, replace the ammeter.
AC Circuit Breaker
1. Disconnect AC cord from the wall outlet and DC plug from the vehicle receptacle.
2. Remove the charger cover.
3. Disconnect the wires from the AC circuit breaker.
4. Place the continuity test probe on the two terminals of the AC circuit breaker. The tester should indicate
continuity. If the tester does not indicate continuity, replace the AC circuit breaker.
Summary of Contents for 2008-2011
Page 2: ......
Page 12: ...Page x 2008 2011 Domestic Battery Charger Maintenance and Service Manual ...
Page 18: ...1 ...
Page 28: ...2 ...
Page 64: ...3 ...
Page 100: ...4 ...
Page 132: ...5 ...
Page 168: ...6 ...
Page 204: ...7 ...
Page 296: ...Club Car R NOTES ...
Page 298: ......
Page 299: ......