PROBLEM
SOLUTION
Modulating Motor Does Not
Operate
1.
Manual-automatic switch in wrong position.
2.
Linkage loose or jammed.
3.
Motor does not drive to open or close during pre-purge or close on burner shut-
down.
a. Motor defective.
b. Loose electrical connection.
c. Damper motor transformer defective.
4.
Motor does not operate on demand.
a. Manual-automatic switch in wrong position.
b. Modulating control improperly set or inoperative.
c. Motor defective.
d. Loose electrical connection.
e. Damper motor transformer defective.
Profire V Burner
Chapter 2
750-177
2-53
O. Burner Specs
Model FLX Burner Characteristics
Model No.
Burner Maximum
Input MBH
Burner Model
Fan Motor (3450 RPM)
Voltage
FLX-150
1500
PFVLG-15
115/230/1/60
FLX-200
2000
PFVLG-20
115/230/1/60
FLX-250
2500
PFVLG-25
115/230/1/60
FLX-300
3000
PFVLG-30
115/230/1/60
FLX-350
3500
PFVLG-35
208/230/1/60
FLX-400
4000
PFVLG-40
208/230/1/60
FLX-450
4500
PFVLG-45
208-230/460/3/60
FLX-500
5000
PFVLG-50
230/460/3/60
FLX-550
5500
PFVLG-55
230/460/3/60
FLX-600
6000
PFVLG-60
460/3/60
FLX-700
7000
PFVLG-70
460/3/60
FLX-800
8000
PFVLG-80
460/3/60
FLX-900
9000
PFVLG-90
460/3/60
FLX-1000
10000
PFVLG-100
460/3/60
FLX-1100
11000
PFVLG-110
460/3/60
FLX-1200
12000
PFVLG-120
460/3/60
Notes:
1.
Burner model selection shown is subject to changed and is based on actual application (altitude, gas pressure, reduced
Summary of Contents for FLX 1000
Page 12: ...Chapter 1 General Description 1 6 750 177...
Page 68: ...Chapter 2 Profire V Burner 2 56 750 177...
Page 90: ...Chapter 4 Sequence of Operation 4 10 750 177...
Page 104: ...Chapter 5 Adjustment Procedures 5 14 750 177...
Page 110: ...Chapter 6 Troubleshooting 6 6 750 177...
Page 122: ...8 2 750 177 Figure 8 1 Typical Hot Water Flextube Casing...
Page 124: ...8 4 750 177 Figure 8 2 Typical Low Pressure Steam Flextube Casing...
Page 126: ...8 6 750 177 Figure 8 3 Typical High Pressure Steam Flextube Casing...
Page 128: ...Parts Chapter 8 8 8 750 177 Steam Pressure Controls...
Page 129: ...Chapter 8 Parts 750 177 8 9 Water Level Controls...
Page 130: ...Parts Chapter 8 8 10 750 177 Water Level Controls continued...
Page 131: ...Chapter 8 Parts 750 177 8 11 Water Column Main and Aux 15 Steam...
Page 132: ...Parts Chapter 8 8 12 750 177 Water Column Main and Aux 150 Steam...
Page 133: ...Chapter 8 Parts 750 177 8 13 Safety Valves...
Page 134: ...Parts Chapter 8 8 14 750 177...
Page 135: ......
Page 136: ...e mail info cleaverbrooks com Web Address http www cleaverbrooks com...