4 - 4
transceiver antennas. providing communication with up to a maximum
of 10 beltpacks depending upon available bandwidth.
Note: To meet FCC emissions requirements a ferrite must be
fitted on any CAT-5 cable plugged into either of the two
ports labeled “tranceivers.” The ferrite should be fitted at
the base station end of the CAT-5 cable. Position the ferrite
as close to the base station as possible. A suitable ferrite is
available from Wurth Elektronix. The part number is 742 711
32.
Note: It is recommended that shielded CAT-5 cable is used for
CellCom 10 systems.
CONNECTING TO PARTY-LINE INTERCOM
SYSTEMS
Up to two channels of party-line intercom can be connected to the
CellCom 10 base station. The descriptions below will discuss
connections with Clear-Com and compatible party-line, RTS party-line,
the ability of CellCom 10 to power a few Clear-Com beltpacks by itself,
and the front-panel settings associated with these party-line
connections.
Using the front-panel display and rotary encoder, the user may go into
the PORTS menu, select the desired party-line channel, and create a
five-character alphanumeric label for it. This is the label that would
then appear on any CellCom 10 wireless beltpacks to which that
party-line connection was assigned for communications. In the
GROUPS menu, the party-line connection can be assigned as a
member of any of the groups, as desired.
CLEAR-COM AND COMPATIBLE PARTY-LINE
Clear-Com and Clear-Com-compatible wired party-line intercoms
connect to the PL CH-A and PL CH-B connectors in a similar manner
to connecting beltpacks or remote stations to the intercom line.
Typically that wired intercom connection would have a 30-VDC current
on Pin 2, coming from a main station or an intercom power supply. The
second connector in the pair may be used as a loop-through to go to
other wired party-line stations or beltpacks, or to a second CellCom 10
base station. The pinout for party line connector is shown in table
Table 4-1.
Summary of Contents for CELLCOM 10
Page 1: ...INSTRUCTION MANUAL CELLCOM 10 DIGITAL WIRELESS Version 1 5 7...
Page 10: ...Vitec Group Communications CellCom 10 Instruction Manual iv...
Page 14: ...Vitec Group Communications CellCom 10 Instruction Manual iv...
Page 16: ...Vitec Group Communications CellCom 10 Instruction Manual ii...
Page 20: ...Vitec Group Communications CellCom 10 Instruction Manual i v...
Page 26: ...Vitec Group Communications CellCom 10 Instruction Manual 1 6...
Page 56: ...Vitec Group Communications CellCom 10 Instruction Manual 4 1 8...
Page 74: ...Vitec Group Communications CellCom 10 Instruction Manual 5 1 8...
Page 91: ...Vitec Group Communications CellCom 10 Instruction Manual 6 1 7...
Page 92: ...Vitec Group Communications CellCom 10 Instruction Manual 6 1 8...
Page 112: ...Vitec Group Communications CellCom 10 Instruction Manual 7 2 0...
Page 120: ...Vitec Group Communications CellCom 10 Instruction Manual 8 8...
Page 128: ...Vitec Group Communications CellCom 10 Instruction Manual 9 8...
Page 140: ...Vitec Group Communications CellCom 10 Instruction Manual 1 0 1 2...
Page 156: ...Vitec Group Communications CellCom 10 Instruction Manual 1 1 1 6...
Page 162: ...Vitec Group Communications CellCom 10 Instruction Manual A 2...
Page 164: ...Vitec Group Communications CellCom 10 Instruction Manual B 2...