222
00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09
11 Fieldwork
11.8 Cleaning unit
67087
– Adjust the cleaning performance monitor sensors.
– Set the sensitivity of the cleaning display and the
desired individual grain loss limit at switch (6).
The display reacts more sensitive / less sensitive,
depending on the adjusted set value.
Check the grain loss limit. Proceed as follows:
– Prepare fieldwork.
– Set the machine depending on the crop. See
threshing chart.
– Engage front attachment.
– Engage the threshing mechanism.
– Drive the machine into the crop at the speed
appropriate for the crop.
– Stop the machine when the forth to fifth light of the
meter light (5) lights up constantly after a sufficient
distance has been covered.
– Check the losses in the swath.
– If loss is at an acceptable level, continue operation
with selected setting.
– When losses on the sieve are too high, increase
the gauge sensitivity by about half to one step,
using switch (6).
Now adjust forward speed until the fourth or fifth
light in the meter light (5) lights up again.
– When excessive losses on the sieve continue,
check the machine setting regarding concave
clearance, drum speed, fan speed and sieve
setting.
When the cleaning is properly adjusted, one of the
lights at the bottom of the meter light (5) lights up.
The cleaning and separation performance monitor
should be adjusted as described to suit changing
losses in the morning, when the crop is wet with dew,
at noon when the crop is absolutely dry, and in the
evening when the crop gradually gets damp.
50
DOMINATOR 150 / 140
19558
51
DOMINATOR 130
19412
6
5
5
6