290
00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09
13 Maintenance
13.5 Engine
67089
86235
13.5.17 Changing the fuel filter
PERKINS 1006-6T
– Observe the general warnings at the beginning of
the "Maintenance" chapter.
– Observe the information provided in the operator's
manual of the engine manufacturer.
– Close the shut-off tap of the fuel system.
– Drain fuel from filter.
- Hold a suitable container for the remaining fuel
in the sight glass (4) beneath the hose.
- Slacken off the drain plug.
- Collect escaping liquid in a suitable container.
- Tighten drain plug.
– Unscrew filter (1) with sight glass (4).
– Clean the inside of the filter head.
– Apply some oil to the new seal and screw new
filter (1) with sight glass (4) to the filter head at
right angles and centred.
– Open the shut-off tap of the fuel system.
Environment!
Lubricants and fuels end up in the
environment.
Environmental pollution.
– Lubricants and fuels must be collected
and stored in suitable containers and dis-
posed of in a way that is harmless to the
environment and in accordance with
existing anti-pollution regulations.
WARNING:
Soiling of fuel system.
Machine damage.
– Make sure surroundings are clean.
– Use suitable and clean tools.
– Ensure that no dirt can enter the fuel
system.
29
29344
1
4
WARNING:
Use of unpermissible spare parts or
lubricants.
Machine damage or increased wear.
– Spare parts and lubricants must at least
comply with the technical standards
required by the manufacturer of the
implement!
– The use of genuine CLAAS spare parts
and lubricants is recommended.