Chapter 3 Configuring Cisco IE 3000 Switch Alarms
Configuring IE 3000 Switch Alarms
Setting a Secondary Temperature Threshold for the Switch
You can use the
alarm facility temperature secondary
global configuration
command to set the low
and high temperature thresholds for the secondary temperature monitoring alarm.
Beginning in privileged EXEC mode, follow these steps to set the low temperature threshold:
Use the
no alarm facility temperature secondary
threshold
global configuration command to disable
the secondary temperature threshold alarm.
This example disables the secondary temperature threshold alarm.
Switch(config) #
no alarm facility temperature secondary 45
Associating the Temperature Alarms to a Relay
By default, the primary temperature alarm is associated to the major relay. You can use the
alarm facility
temperature
global configuration
command to associate the primary temperature alarm to the minor
relay, to an SNMP trap, to a syslog message, or to associate the secondary temperature alarm to the major
or minor relay, an SNMP trap, or a syslog message.
Beginning in privileged EXEC mode, follow these steps to associate the secondary temperature alarm to
a relay:
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
alarm facility temperature
secondary high
threshold
Set the secondary high temperature threshold value. Set the threshold from
–238°F (–150°C) to 572°F (300°C).
Step 3
alarm facility temperature
secondary low
threshold
Set the secondary low temperature threshold value. Set the threshold from
–328°F (–200°C) to 482°F (250°C).
Step 4
end
Return to privileged EXEC mode.
Step 5
show alarm settings
Verify the configuration.
Step 6
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
alarm facility temperature
{
primary
|
secondary
}
relay
{
major
|
minor
}
Associate the primary or secondary temperature alarm to a relay.
Step 3
alarm facility temperature
{
primary
|
secondary
}
notifies
Send primary or secondary temperature alarm traps to an SNMP server.
Step 4
alarm facility temperature
{
primary
|
secondary
}
syslog
Send primary or secondary temperature alarm traps to a syslog server.
Step 5
end
Return to privileged EXEC mode.
Step 6
show alarm settings
Verify the configuration.
Step 7
copy running-config startup-config
(Optional) Save your entries in the configuration file.