5-7
Cisco IE 3000 Switch Software Configuration Guide
OL-13018-03
Chapter 5 Configuring Cisco EnergyWise
Managing Single Entities
Configuring Entity Attributes
Beginning in privileged EXEC mode:
Command
Purpose
Step 1
show energywise
(Optional) Verify that EnergyWise is enabled.
Step 2
configure terminal
Enter global configuration mode.
Step 3
energywise importance
importance
(Optional) Set the importance of the entity.
The range is from 1 to 100.
The default is 1.
Step 4
energywise keywords
word,word,
...
(Optional) Assign at least one keyword for the entity.
When assigning multiple keywords, separate the keywords with
commas, and do not use spaces between keywords.
•
You can enter alphanumeric characters and symbols such as
#, (, %, !, or &.
•
Do not use an asterisk (*) or a blank space between the
characters and symbols.
By default, no keywords are defined.
Step 5
energywise management
udp-port-number
(Optional) Specify the UDP port that sends and receives queries.
The range is from 1 to 65000.
The default is 43440.
Step 6
energywise name
name
(Optional) Specify the EnergyWise-specific entity name.
•
You can enter alphanumeric characters and symbols such as
#, (, %, !, or &.
•
Do not use an asterisk (*) or a blank space between the
characters and symbols.
The default is the hostname.
Step 7
energywise neighbor
[
hostname
|
ip-address
]
udp-port-number
(Optional) Assign a static neighbor.
•
(Optional) Hostname (
hostname
) or IP address (
ip-address
).
•
UDP port (
udp-port-number
) that sends and receives queries.
The range is from 1 to 65000.
By default, no static neighbors are assigned.
Step 8
energywise role
role
(Optional) Specify the role of the entity in the EnergyWise
domain. For example, lobby.b20.
•
You can enter alphanumeric characters and symbols such as
#, (, %, !, or &.
•
Do not use an asterisk (*) or a blank space between the
characters and symbols.
The default is the model number.
Step 9
end
Return to privileged EXEC mode.