17-3
Catalyst 3550 Multilayer Switch Software Configuration Guide
78-11194-03
Chapter 17 Configuring System Message Logging
Configuring System Message Logging
This example shows a partial switch system message:
00:00:46: %LINK-3-UPDOWN: Interface Port-channel1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to up
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed
state to down 2
*Mar 1 18:46:11: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
18:47:02: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
*Mar 1 18:48:50.483 UTC: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
Default System Message Logging Configuration
Table 17-2
shows the default system message logging configuration.
MNEMONIC
Text string that uniquely describes the message.
description
Text string containing detailed information about the event being reported.
Table 17-1
System Log Message Elements (continued)
Element
Description
Table 17-2
Default System Message Logging Configuration
Feature
Default Setting
System message logging to the console
Enabled.
Console severity
Debugging (and numerically lower levels; see
Table 17-3 on page 17-9
).
Logging buffer size
4096 bytes.
Logging history size
1 message.
Timestamps
Disabled.
Synchronous logging
Disabled.
Logging server
Disabled.
Syslog server IP address
None configured.
Server facility
Local7 (see
Table 17-4 on page 17-12
).
Server severity
Informational (and numerically lower levels; see
Table 17-3 on page 17-9
).