g709 otu threshold
To configure thresholds for selected Optical Channel Transport Unit (OTU) bit error rate (BER) alarms, use
the
g709 otu threshold
command in DWDM configuration mode. To return to the default state, use the
no
form of this command.
g709 otu threshold
{
sd-ber| sf-ber
}
bit-error-rate
no g709 otu threshold
{
sd-ber| sf-ber
}
bit-error-rate
Syntax Description
Signal degradation bit error rate (BER) in the range 1 to 9, where
bit-error-rate
specifies a negative exponent of base 10 (10
–
bit-error-rate
). The default is 6
(10
–
6).
sd-ber bit-error-rate
Signal failure BER above threshold in the range 1 to 9, where
bit-error-rate
specifies a negative exponent of base 10 (10
–
bit-error-rate
). The default is 3
(10
–
3).
sf-ber bit-error-rate
Command Default
The defalut bit error rate for
sd-ber
is 6.
The default bit error rate for
sf-ber
is 3.
Command Modes
DWDM configuration
Command History
Modification
Release
This command was introduced.
Release 3.9.0
Usage Guidelines
To use this command, you must be in a user group associated with a task group that includes appropriate task
IDs. If the user group assignment is preventing you from using a command, contact your AAA administrator
for assistance.
Task ID
Operations
Task ID
read, write
dwdm
Examples
This example shows how to set the signal fail BER rate to be 5:
RP/0/RSP0/CPU0:router(config)#
controller dwdm 0/0/0/0
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
19
Dense Wavelength Division Multiplexing Commands on the Cisco ASR 9000 Series Router
g709 otu threshold