Task ID
Operations
Task ID
read, write
ethernet-services
Examples
This example shows how to configure the time interval at which continuity-check messages are transmitted
and set the threshold limit for when a MEP is declared down.
RP/0/RSP0/CPU0:router#
configure
RP/0/RSP0/CPU0:router(config)#
ethernet cfm
RP/0/RSP0/CPU0:router(config-cfm)#
domain Domain_One level 1 id string D1
RP/0/RSP0/CPU0:router(config-cfm-dmn)#
service Bridge_Service bridge group BD1 bridge-domain
B1
RP/0/RSP0/CPU0:router(config-cfm-dmn-svc)#
continuity-check interval 100ms loss-threshold
10
Cisco ASR 9000 Series Aggregation Services Router Interface and Hardware Component Command Reference,
Release 5.3.x
192
Ethernet OAM Commands on the Cisco ASR 9000 Series Router
continuity-check interval