A-72
METAL DOT MATRIX
REV. 04.2002
A THE MACHINE'S SETUP
OPERATORS MANUAL
A.13 CARD TEST LIST
To make a card test connect the keyboard to the
rear DIN connector and select the mode
(continous, without card, ) by means of the F5
key.
Then press the key F3 and the number of the card
test (see the list below) and press Enter.
The card test presently available for METAL DOT
MATRIX models are shown in the following table.
0
Stamp all characters
1
Stamp an "L" in each angle of the card
5
Stamp a plate with all the machine setup
6
Stamp a CIM fixed text
7
Stamp enabled logos (see the STAMPING
CONFIGURATION menu to see how to enable
the logos for stamping)
Note: with regard to the Card Tests 0, 5 and 6, the
intercharacter and interline spaces depend to
the value of the setup parameters BLOC CHAR
SPACING and BLOC LINE SPACING of the protocol
menu.
A.14 RESET OF THE MACHINE
To reset the machine in each moment press the
following key sequence:
F 10
.
REV. 05-2008
Summary of Contents for MDM 1000
Page 1: ......
Page 5: ...0 5 METAL DOT MATRIX 0 FOREWORD...
Page 6: ...0 6 METAL DOT MATRIX REV 04 2002 0 FOREWORD OPERATORS MANUAL REV 05 2008...
Page 9: ...1 9 METAL DOT MATRIX GENERAL INFORMATION 1...
Page 19: ...2 19 METAL DOT MATRIX UNPACKING 2...
Page 21: ...3 21 METAL DOT MATRIX INSTALLATION 3...
Page 27: ...4 27 METAL DOT MATRIX OVERALL DESCRIPTION 4...
Page 33: ...5 33 METAL DOT MATRIX HOW TO PRODUCE ONE CARD 5...
Page 43: ...6 43 METAL DOT MATRIX MAINTENANCE 6...
Page 47: ...7 47 METAL DOT MATRIX TROUBLESHOOTING 7...
Page 73: ...B 73 METAL DOT MATRIX HOW TO UPDATE THE FW ANNEX B...
Page 77: ...C 77 METAL DOT MATRIX LCD EDIT ANNEX C...
Page 99: ......