Operation
Roadster & Mirage S+/HD User Manual
3-43
020-100002-04 Rev. 1 (12-2008)
Separate
RS232 and RS422 Joined
Ethernet Joined
All Joined
RS232 and
1.
2.
3.
4.
SEPARATE:
Select “Separate” (factory default) to keep RS232, RS422 and Ethernet
messages on their respective paths instead of being broadcast to the other types of
ports. In Figure 3.19A, RS422 controls only the projector to which it is connected. In
Figure 3.19B; either RS232 or RS422 will control the network.
Figure 3.19. Using the “Network Routing” Option
RS232 AND RS422 JOINED:
Messages originating from an RS232 or RS422 controller
will be relayed to all RS232or RS422 ports. Any Ethernet communication, however,
will not.
RS232 AND ETHERNET JOINED:
Messages to and from the RS232 ports will also be
relayed to the Ethernet port, and vice versa. Any RS422 communications will be
isolated.
ALL JOINED:
All messages reach all ports, regardless of type.
Ethernet Settings
(SUBMENU)
NOTE:
Recommended for network administrators only.
DHCP:
Enable this checkbox if you want a DHCP server to automatically change the
projector’s default IP address (0.0.0.0) to one that is valid and unique for use on the
current Ethernet network. On networks without a DHCP server, or to simply override
the automatic DHCP server function, delete the checkmark and enter the new “IP
Address” settings desired. Remember that only a 0.0.0.0 address will trigger the