3-18
CP2000-SB User Manual
020-100162-06 Rev. 1 (03-2014)
Section 1: Introduction
3.5.4 TPC Custom Menu
NOTE:
Password-protected; Requires Advanced, Admin, or Installer rights.
The TPC's five
Custom
menus enable installers (service), administrators or advanced users to tailor projector
processing as they wish for any type of incoming source, including 3D material, and collect these settings into
a unique channel that any user can select at the Main menu. Up to 32 channels can be defined.
SAVING OR DELETING:
Changes in the
Custom
menu are saved when you leave the menu. Or, to delete
one or more channels, use the trash bin
Delete
button-note a caution dialog box will appear first.
Custom: Page-1
and Page-2
These two menus consist of numerous display settings that can be adjusted as desired, then defined collectively
as a custom setup or channel. Each defined channel then appears as a button on the
Main
menu where any user
can select it, providing a reliable way to quickly and correctly change the on-screen display to suit the source
content. Alternatively, if a pre-defined
Projector Configuration File (PCF)
has been supplied with distributed
content (rare) and the
Use PCF
checkbox checked, those
Custom
options which are already defined in the
PCF (Source, Target Color, Color Space, Gamma and LUT-CLUT) disappear from the
Custom
menus and are
protected from further modification. The channel defined in such a case will thus be based on 1) the display
settings in the supplied PCF and 2) the remaining
Custom
parameters that are not contained in a PCF: the
physical location of the input connection (such as a cinema port or DVI port), the screen format, data format,
and processing path.
OTHER
SSM Communication Error
Check cabling. Cycle projector power for a normal start-up. Check LEDs on card cage boards,
which can indicate a light engine problem instead. Check LVPS/Processor voltages. Also, if
shutter or lamp are functioning normally, SSM likely OK.
I
2
C Communication Error
There may be a power problem with the main electronics (I
2
C). Check LVPS/Proc. voltage
adjustments.
LENS MOUNT
A communications error with the ILS motor
control board has occurred. Please ensure
that all cabling is correctly connected.
Check cabling. Cycle projector power for a normal start-up.
ILS Motor Control Board - Sensor Failure
This error will only be detected on a lens reset or lens calibrate. Check the sensors. It is cleared
by cycling the projector power or performing a lens reset.
ILS Motor Control Board - In Boot/Program
Mode
If this message remains for longer than 4 seconds, try re-powering the TPC or upgrading the
MCB software.
ILS Motor Control Board - Main Code CRC
Upgrade MCB software.
Summary of Contents for CP2000-SB
Page 1: ...CP2000 SB U S E R M A N U A L 020 100162 06 ...
Page 9: ......
Page 15: ...1 6 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Page 155: ...8 8 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Page 157: ...8 10 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Page 173: ...A 16 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...