Section 1: Introduction
CP2000-SB User Manual
B-15
020-100162-06 Rev. 1 (03-2014)
B.2
Messages with Multiple Parameters
Certain messages are more complex and require multiple parameters in order to relay complete information.
These messages are described in detail below.
B.2.1 Error Messages (ERR)
An error message is generated by the projector/TPC, and contains a numerical error code, a message specifier
(i.e., type of error, such as "
System Error
"), and a text explanation of the error. In addition, "
System
Error
" and "
System Warning
" error messages also include further explanation of the nature of the error,
such as its location and cause.
NOTE:
The type of error and text parameters are enclosed together in
quotation marks, separated by a colon and space. In the table below, the text explanation appears as -----.
Table B.2 Error Messages
Additional Parameters for "001" System Errors and "002" System Warnings
"System Error" and "System Warning" error messages include two additional parameters (P3 and P4), which
further describe the error. P3 indicates what component or system is involved (such as interlocks, fans,
temperature, SSM communication, or a lamp failure) and P4 relays the specific condition detected at the
suspect component, such an over-temperature reading or a slow fan speed reading-note these values indicate
temperature or fan speed only. See
Table B.3
,
Table B.4
, and
Table B.5
.
When a system error is resolved and is no longer present, another message reports this by replacing the first
digit in the original P3 error code with a "1".
Error Code (P1)
Type of Error (P2)
Meaning
001
"System Error: -----"
"System critical error.
002
"System Warning: -----"
"System error.
003
"Invalid parameter-"
"Invalid parameter number.
004
"Too many parameters"
"Message requires fewer parameters
005
"Too few parameters"
"Message requires more parameters
006
"Source does not exist"
"The source # is wrong
007
"Could not be executed"
"Current content prevented the command from executing.
008
"Checksum error"
"The checksum is incorrect.
009
"Unknown request"
"Message code undefined. If the message sent as a command it is
ignored and no error is returned.
010
"Communication error"
"Error receiving serial data on one of the RS-232 ports.
Summary of Contents for CP2000-SB
Page 1: ...CP2000 SB U S E R M A N U A L 020 100162 06 ...
Page 9: ......
Page 15: ...1 6 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Page 155: ...8 8 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Page 157: ...8 10 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Page 173: ...A 16 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...