Section 1: Introduction
CP2000-SB User Manual
3-57
020-100162-06 Rev. 1 (03-2014)
3.8
Working with the Lamp
Simple software controls and adjustments can help to optimize lamp performance and ensure the brightest,
most uniform image possible for the life of the lamp. These controls are located in the Main, Advanced:
Preferences, and Advanced: Lamp menus on the TPC.
NOTE:
For individual menu functions, refer to
Section 3.5 Using the Touch Panel Controller (TPC)
.
3.8.1 Turning the Lamp ON/OFF
ON
With all CP breakers set to ON, ignite the lamp by pressing the lamp button on the
Main
menu of the TPC-
make sure to press and hold for approximately ½ second.
OFF
To turn the lamp OFF, press the lamp button on the
Main
menu of the TPC-make sure to press and hold for
approximately ½ second. Then
WAIT
for fans to run for 10 minutes to cool the lamp and other compo-
nents then turn off all breakers.
3.8.2 If the Lamp Won't Turn ON
If the lamp fails to ignite, the projector will automatically re-try ignition using 100% of the maximum power
acceptable for the lamp. If this re-try also fails, and there is no interlock problem such as an open lamp door, a
new lamp is likely needed.
Figure 3-45 Lamp Button on TPC
Lamp ON/OFF -
Select and hold
for 1/2 second.
Summary of Contents for CP2000-SB
Page 1: ...CP2000 SB U S E R M A N U A L 020 100162 06 ...
Page 9: ......
Page 15: ...1 6 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Page 155: ...8 8 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Page 157: ...8 10 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Page 173: ...A 16 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Page 197: ...B 24 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...