3-62
CP2000-SB User Manual
020-100162-06 Rev. 1 (03-2014)
Section 1: Introduction
3.8.5 Stand-by Mode
Close the douser (shutter) to put the projector in a
cooler stand-by mode where lamp power is
reduced to 50% of its maximum rating. Upon
opening the douser and restoring the image, the
lamp power will return to its previous setting.
3.8.6 How Old is My Lamp?
When a new lamp is installed and its serial number
recorded (
Advanced: Lamp
menu), the lamp
timer resets to
0
and begins logging time for the new lamp. This total appears in both the Advanced: Lamp
menu and the Status menu. See right.
The Status menu also shows
Total Lamp Hours
, which is the accumulated time logged for all lamps installed
thus far. Each past lamp log also appears in the
Advanced: Lamp
History menu.
Figure 3-51 Lamp Power in Stand-by Mode
50% lamp
power when
closed.
Figure 3-52 Lamp Hours