37/40
Notes
13.6
Other
Description
Remedy / Reason / Solution
14
Technical Data
14.1
General
Technical Data
Barrier closes as soon as loop has been unblocked
Normal control unit function. Delay has to be
set at loop diagnosis unit.
Barrier comes to standstill during travel
Power failure during operation. See also:
Barrier does not work.
BARS1
BARS3
BARM6
BARL6
Opening Time (Seconds)
1
3
6
6
Closing Time (Seconds)
1
3
6
6
Max. Length Straight Boom (mm)
2500
4500
6000
8000
Max. Length 90° Folding Boom (mm)
-
3200
-
-
Max. Length 180° Folding Boom (mm)
-
3020
-
-
Duty Rating (%)
100
100
100
100
Max. Cycles per Day
900
500
200
200
Warranty (Years)
2
2
2
2
Voltage IN (V)
220-240
220-240
220-240
220-240
Frequency (Hz)
50
50
50
50
Consumption Nominal (A)
1
1
1
1
Power (W)
100
120
120
120
Motor Voltage (V)
230
230
230
230
Motor RPM (rpm)
933
933
933
933
Capacitor (µF)
9+9
9+9
9+9
9+9
Rating of Housing (IP)
45
45
45
45
Rating Control Board Box (IP)
56
56
56
56
Temp. Range (°C)
-25°/75°
-25°/75°
-25°/75°
-25°/75°
Cooling Fan for Motor
-
yes
yes
yes
Overheat ProtectionMotor (°C)
140
140
140
140
Housing:
Width Door Side (mm)
325
325
325
325
Depth (mm)
282
282
282
282
Height (mm)
930
930
930
930
Pivot Point / Bar Height (mm)
830
830
830
830
Housing Color Standart (RAL)
2003
2003
2003
2003
Weight with Transport Box (kg)
60
60
60
60