10.5.2 Description of socket connectors
• SHORTCUT CONNECTOR:
terminal blocked for particular type of loop detector. Cable not
included in range of offer. Serves the same purpose as the VEHICLE DETECTOR SIGNAL
• CAPACITOR X2:
capacitor terminal
o Power: 2x 9μF/450Volt
o Clamp occupancy from left to right:
• COM
• C1
• C2
• LIMIT SIGNAL INPUT:
limit switch terminals
o Terminals for limit switches
o Clamp occupancy from left to right:
• Red
• Green
• Yellow
• Black
• SENSOR:
rotation sensor terminal
o Sensor monitors motor rotational speed. If barrier is brought to a standstill (hits obstacle) during
travel (down) the barrier reverses. The sensor is located at the bottom of the motor and is
equipped with LED’s for operation control.
o Clamp occupancy from top to bottom:
• Red
• Black
• Brown
• RADIO RECEIVER:
external radio terminal
o Terminal for radio receiver, which is installed outside of the control in a suitable casing.
The connecting wire is included in delivery contents of standard barrier models. If a signal is
transmitted from the radio receiver to the control, then the beeper on the control unit sounds as
a means of verification and indication for the time of the given impulse.
o Possible receiver models
• 8002E 2-channle, 15 remote controls each per channel IP57
• STAR250-433, 1-channel Management System for 250x remote controls; box for external
installation must be ordered separately
NOTE: in order to use a radio code lock a receiver of the above mentioned models is necessary
o Clamp occupancy from left to right
• COM 5V
COM
red
• Stop
signal stop
black
• Down
signal close
yellow
• Up
signal open
green
• Not occupied
brown
• TEST:
Motor fan terminal (in barrier motor)
o Operation of fan is possible via TEST switch
o Not all barrier models are fitted with a fan ex works
o Clamp occupancy from left to right
• - (minus)
• Test
• + (plus)
• COMMUNICATION MODULE
o Socket presently not usable
A
B
C
D
G
E
F