Installation Guide for FibeAir IP-20C-HP
Page 158 of 204
Ceragon Proprietary and Confidential
Procedure
1 Before attaching the U-Bend, make sure that the U-Bend is already fitted with
bushings in both ports. The U-Bend should be supplied with bushings to seal
the RF.
2 Long U-Bends are connected between adjacent radio ports on opposite sides
of the Branching Pole Profile. Place the U-Bend so that the embedded #8-32
socket hex screws are in line with the radio ports of the OCUs, as shown in the
figure below. Make sure the sealing gaskets supplied with the U-Bend are in
place before mounting the U-Bends.
Sealing Gaskets
Sealing
Gaskets
1
2
1
Radio/OCU 2
Radio/OCU 3
Radio/OCU 4
Radio/OCU 1
Use 2.5 Nm Torque