Installation Guide for FibeAir IP-20C-HP
Page 121 of 204
Ceragon Proprietary and Confidential
Procedure
1 Mount the OMT (for dual polarization) or Splitter (for single polarization) to
the antenna and secure it with four screws.
Important:
Verify that the O-ring is properly mounted between the antenna
transition and the OMT/Splitter.
OMT
O-Ring
2 If you are using a Splitter, adjust the twist on the Splitter Kit. Perform one of
the following steps, according to the required polarization (horizontal or
vertical).
For horizontal polarization, locate the twist with
the letter “H”
on top.