6.11
2 x 2+0 Dual Polarization Remote Mount
Note!
This procedure can also be used for 2 x 1+0 DP HW ready for 2 x 2+0
DP configurations.
List of Items
Item
Description
Quantity
Marketing Model
1
IP-20C-HP RADIO
2
See Section 2.4.1,
2
IP-20C-HP Diplexer Unit
2
See Section 2.4.2,
3
IP-20C-HP OMT KIT
1
DXDH-MD-OMT-
ff
4
IP-20C-HP DUAL COUPLER or
SPLITTER KIT
1
DXDH-MD-DUAL-CPLR-
ff
DXDH-MD-DUAL-SPLTR-
ff
5
FLEXIBLE WG KIT
2
6
IP-20C-HP DC POLE MOUNT
KIT
1
DXDH-RM-MOUNT-ADPT-
ff
7
IP-20C-HP DC REMOTE
MOUNT ADAPTOR KIT
1
DXDH-RM-MOUNT-ADPT-
ff
Not Required for 4-5 GHz
8
CIRC./CIRC. ADAPTOR
1
Per Antenna Vendor
Required Tools
•
Metric offset hexagon key set
•
Metric wrench key set
•
Phillips #1, #2 screwdriver