4
Make sure the following items are attached to the Dual Coupler or Splitter
before attaching the Diplexer units:
•
Four plastic washers on either side of the Dual Coupler or Splitter on the
surface around the screw threads for the Diplexer unit.
•
Smooth tin foil sheets on the side facing the waveguide interfaces. Make
sure they are properly placed and not bent or wrinkled. It is also
important to ensure that the tin foil sheets do not get wrinkled or bent
during installation.
5
Attach the Diplexer unit to the Dual Coupler or Splitter using 8 M4 screws
provided with the Diplexer kit, as shown below, using 20Nm torque.
Important:
Verify that the O-rings on the Dual Coupler or Splitter are properly
mounted between the Dual Coupler or Splitter ports and the Diplexer
unit.