Installation Guide for FibeAir IP-20C-HP
Page 55 of 204
Ceragon Proprietary and Confidential
4 Roll back the foil shield insulation and wrap the drain wire around the foil. Do
not remove any insulation from the conductors.
5 Align the colored wires.
Note:
Cord colors should be matched to the same pins on both ends of the
cable.
6 Trim all wires to the same length. About 12 mm on the left should be exposed
from the inner sheath.
7 Separate the wires and place the twisted shield between the separated wires.
8 Insert the wires into the RJ45 plug. Verify that each wire is fully inserted into
the front of the RJ45 plug and in the correct order, according to the pinouts
shown in
Outdoor Ethernet Cable Specifications
on page 38. The sheath of the
Ethernet cable should extend into the plug by about 13 mm and held in place
by the crimp.
9 Extend the cable jacket with the shield into the connector about 5 mm for
strain relief and shielding connection.
10 Wrap the twisted braid firmly around the cable jacket and let the crimping tail
of the RJ45 plug envelop it.
Important Note!
To ensure proper grounding, it is essential that the twisted
braid be firmly connected to the RJ45 plug.