background image

Installation Guide for FibeAir IP-20C-HP  

 

 

 

 

Page 113 of 204 

 

Ceragon Proprietary and Confidential

 

  

2  Mount the Splitter Kit on the antenna using four M8 screws and washers and 

tighten the screws. 

 

3  Connect the IP-20C-HP DC radio to the Splitter kit using the four M8 captive 

screws and washers supplied, and tighten the screws. 

Important:

 Verify that the O-rings are properly mounted between the OMT ports 

and the radio/dual coupler.  

Summary of Contents for FibeAir IP-20C-HP

Page 1: ...Installation Guide FibeAir IP 20C HP June 2019 Rev B 03 Copyright 2019 by Ceragon Networks Ltd All rights reserved...

Page 2: ...ay use open source software among them O S software released under the GPL or GPL alike license Open Source License Inasmuch that such software is being used it is released under the Open Source Licen...

Page 3: ...o Components 16 2 2 2 Diplexer Based Branching Branching Components 17 2 2 3 Diplexer Based Branching Accessory Components 19 2 3 System Components Channel Filter Based Branching 20 2 4 IP 20C HP Mode...

Page 4: ...ection Signaling Cable 60 5 General Notes Concerning All Installation Procedures 61 6 Installation Instructions for Configurations with Diplexer Based Branching 62 6 1 Torque Requirements 62 6 2 Gener...

Page 5: ...Channel Filter Based Branching Configurations 162 7 2 1 2 0 Single Polarization 162 7 2 2 2 0 Dual Polarization 164 7 2 3 4 0 Single Polarization 166 7 2 4 4 0 Dual Polarization 168 7 2 5 6 0 Single...

Page 6: ...21 Figure 17 Termination 21 Figure 18 Cable Grounding 31 Figure 19 Cable Design 37 Figure 20 Tightening the Front Portion of the Gland 46 Figure 21 Tightening the Rear Portion of the Gland 46 Figure 2...

Page 7: ...Figure 39 Left Rail Configuration 150 Figure 40 Right Rail Configuration 150 Figure 41 Left and Right Rail Configurations Together 151 Figure 42 Attaching the Radio to the OCU 151 Figure 43 Order of...

Page 8: ...Table 7 Placeholder Definitions for OCU Marketing Models 25 Table 8 IP 20C HP OCU Marketing Model Example 25 Table 9 IP 20C HP Branching Unit Marketing Models 26 Table 10 Antenna Flanges 27 Table 11 G...

Page 9: ...rts and frequency bands What You Should Know For the warranty to be honored install the unit in accordance with the instructions in this manual Target Audience This guide contains technical informatio...

Page 10: ...the compliance boundary distance is 0 Note that even when the compliance boundary is a non zero value this only applies within the bore sight of the antenna dish Therefore during work within and clos...

Page 11: ...let utstyr og er tilkoplet et kabel TV nett kan for rsake brannfare For unng dette skal det ved tilkopling av utstyret til kabel TV nettet installeres en galvanisk isolator mellom utstyret og kabel TV...

Page 12: ...ort deck side shipment is not permitted Carrier owned cargo containers should be used It is recommended that the equipment be transported to the installation site in its original packing case If inter...

Page 13: ...he addition of a single IP 20C HP unit and antenna at each end of the link while utilizing the same exact frequency channel with no network replanning IP 20C HP can be used with wide diplexer based br...

Page 14: ...204 Ceragon Proprietary and Confidential 2 1 IP 20C HP Hardware Overview IP 20C HP features an all outdoor dual carrier architecture consisting of a single unit Figure 1 IP 20C HP Rear View Left and...

Page 15: ...ctric 10 100 1000Base T RJ 45 Data Port 2 for GbE traffic Optical 1000Base X SFP Data Port 3 EXT Optical 1000Base X SFP Optical Ceragon proprietary interface if this port serves as an extension port f...

Page 16: ...IP 20C HP in a specific band as well as the availability of any specific mediation device Presenting a specific component in this manual does not indicate that it is available for ordering Please con...

Page 17: ...Installation Guide for FibeAir IP 20C HP Page 17 of 204 Ceragon Proprietary and Confidential 2 2 2 Diplexer Based Branching Branching Components Figure 6 OMT Figure 7 Space Diversity Branching Device...

Page 18: ...Installation Guide for FibeAir IP 20C HP Page 18 of 204 Ceragon Proprietary and Confidential Figure 8 Splitter Figure 9 Dual Coupler Splitter Circulator...

Page 19: ...allation Guide for FibeAir IP 20C HP Page 19 of 204 Ceragon Proprietary and Confidential 2 2 3 Diplexer Based Branching Accessory Components Figure 10 Remote Pole Mount Figure 11 Remote Pole Mount Ada...

Page 20: ...and as well as the availability of any specific mediation device Presenting a specific component in this manual does not indicate that it is available for ordering Please consult with your pre sales e...

Page 21: ...Installation Guide for FibeAir IP 20C HP Page 21 of 204 Ceragon Proprietary and Confidential Figure 16 Splitter Coupler Figure 17 Termination...

Page 22: ...e 1 defines the radio unit marketing model placeholders Table 2 provides examples of actual IP 20C HP radio unit marketing models Table 1 IP 20C HP Radio Unit Marketing Model Placeholders Placeholder...

Page 23: ...ng models Table 3 IP 20C HP Diplexer Unit Marketing Model Placeholders Placeholder in Marketing Model Description Possible Values ff Frequency band 6L 6H 7 8 10 11 xxxY TX RX separation and block indi...

Page 24: ...DXDH RM MOUNT ADPT ff IP 20C HP DC Adaptor Remote Mount Kit ff GHz DXDH RM MOUNT kit 4 5 IP 20C HP Remote Mount Kit 4 5GHz DXDH RM OMT ADPT ff IP 20C HP DC OMT Adaptor ff GHz DXDH MD DUAL CIRC ff IP 2...

Page 25: ...n Ceragon internal xxx TRS 3 figures in MHz Y Letter to indicate frequency block Example 266A The frequency block is a Ceragon internal parameter which defines different channelization using the same...

Page 26: ...anching Unit Marketing Models Marketing Model Description FXDH RM MOUNT kit IP 20C HP OCU Mounting Kit FXDH RM U Bend ff IP 20C HP Filters Cover Branching U Bend FXDH RM LU Bend ff IP 20C HP FLT Cover...

Page 27: ...used recommended Other antenna types using the flanges listed in the table below may also be used Table 10 Antenna Flanges Frequency Band Range GHz Rect WG Flange Des Radio Side Remote Flange Des 4 G...

Page 28: ...ction to protective grounding Data port 2 Data port 3 the Management port and the TNC connector do not provide protection from over voltages on telecommunication networks for host equipment users The...

Page 29: ...ric wrench 10mm Procedure 1 On the front of each IP 20C HP unit loosen the nut plain washer and serrated washer from the GND stud using the metric offset hexagon key and the wrench 2 Place the cable l...

Page 30: ...e unit s earthing screw terminal shall be permanently connected to protective earth in a building installation in accordance with applicable national code and regulations by a service person Any outdo...

Page 31: ...s follows For fiber cables see Connecting an Optical Fiber Cable and SFP on page 47 no grounding is required For DC power cables see Connecting a DC Power Cable on page 51 no grounding is required For...

Page 32: ...beAir IP 20C HP Page 32 of 204 Ceragon Proprietary and Confidential To connect the grounding kit 1 Strip the cable jacket 2 Place the cable in the middle of the grounding bracket 3 Close the grounding...

Page 33: ...rectly to the tower 6 Tighten the grounding lug 4 3 Power Source The power cable must be plugged into the unit before turning on the external power When selecting a power source the following must be...

Page 34: ...cur it is strongly recommended to add additional protection by placing lightning protectors on all electrical Ethernet cables near the connection points with the IP 20C HP unit 4 5 Available Cable Opt...

Page 35: ...DUAL LC LC 80M MM 55mm OPEN END M28 GLAND ARMORED O IP 20_FO_MM_LC2LC_ARM_100m CABLE FO DUAL LC LC 100M MM 55mm OPEN END M28 GLAND ARMORED IP 20_FO_MM_LC2LC_ARM_150m CABLE FO DUAL LC LC 150M MM 55mm O...

Page 36: ...pltr IP 20C MIMO or Prot management odu spltr 4 5 5 Ethernet Cable and Specifications Table 17 Ethernet Cable and Specifications Marketing Model Description CAT5E_SFUTP_Outdoor_50m CABLE RJ45 TO RJ45...

Page 37: ...rs in the figure below refer to the items listed beneath the figure Figure 19 Cable Design 1 Conductor 2 Insulation 3 Screen Alu Pet foil Alu outside 4 Tinned copper braid 5 Jacket Table 18 Ethernet C...

Page 38: ...CAT 5e SFUTP 4 pairs according to ANSI TIA EIA 568 B 2 Wire gage 24 AWG Stranding Solid Voltage rating 70V Shielding Braid Foil Pinout Mechanical Environmental Requirements Jacket PVC double UV resis...

Page 39: ...14 AWG for 328ft installations 9 AWG for 328ft installations Stranding stranded Voltage rating 600V for 9 AWG 300V for 14 AWG Spark test 4KV Dielectric strength 2KV AC min Mechanical Environmental Req...

Page 40: ...ps kit take special care to apply the proper amount of force in order to avoid damage to the cable This is especially important for optical SFP cables The following cable clamps are available Table 19...

Page 41: ...20_Glands_kit IP 20_Glands_x5_kit In addition gland caps can be ordered to protect the cable and connector from damage when elevating the cable and gland to the radio unit See Step 5 in Section 4 7 1...

Page 42: ...n Procedure This procedure applies to all cable types and explains how to install the cables using long glands The gland is supplied assembled 1 Before inserting a cable you must disassemble the gland...

Page 43: ...nd cap see Step 5 make sure to leave enough space for the gland cap to fit into the gland without disturbing the cable 5 Optionally after securing the cable into the body of the gland you can close th...

Page 44: ...u can connect a rope to the hook and use this to lift the gland and cable up to the radio unit Before screwing the gland into the radio unit you must remove the gland cap 7 If you used an M28 gland ca...

Page 45: ...ealing of the interface 10 Insert the main part of the gland into the thread in the radio body and tighten until there is full contact and the gasket is fully contained between the gland and the radio...

Page 46: ...he main part of the gland does not have an additional swivel after the rear portion is secured Note If the main portion of the gland is rotated while the rear portion is seizing the cable this may rui...

Page 47: ...Optical Fiber Cable and SFP To connect an optical fiber cable and the SFP transceiver 1 Use a pre assembled cable 2 Split the connector into two separate LC connectors one for each fiber 3 Remove the...

Page 48: ...t the fibers with the connectors one by one into the cable gland 7 Secure the cable to the lip of the gland using a tie wrap Important Note If you are raising the cable to a radio unit on a tower this...

Page 49: ...sure that they are fully inserted 9 Remove the tie wrap securing the cable to the gland Note A new tie wrap must be used to secure the cable to the gland at the end of the procedure as described in St...

Page 50: ...the unit Tightening the gland at an angle can ruin the thread on the gland and prevent proper sealing of the interface Tighten the gland gently and make sure there is no resistance If there is resista...

Page 51: ...ordered separately See DC Cable and Connector on page 35 To connect a DC power cable 1 Strip off 45 mm from the cable jacket 2 Expose 10 mm at the edge of each of the two wires 3 Insert the power cab...

Page 52: ...Guide for FibeAir IP 20C HP Page 52 of 204 Ceragon Proprietary and Confidential 6 Tighten the two top screws 7 Plug the power cable with connector into the IP 20C HP power connector 8 Tighten the two...

Page 53: ...re the gland is even with the cover Tighten the gland gently and make sure there is no resistance If there is resistance stop immediately and verify that the gland is not being inserted at an angle Ti...

Page 54: ...the RJ 45 plug must be shielded with a crimping tail Table 22 Materials for Preparing Ethernet Data Cables Marketing Model Description CAT5E_SFUTP_Outdoor_50m CABLE RJ45 TO RJ45 STR 50M CAT 5E ETHER U...

Page 55: ...separated wires 8 Insert the wires into the RJ45 plug Verify that each wire is fully inserted into the front of the RJ45 plug and in the correct order according to the pinouts shown in Outdoor Ethern...

Page 56: ...and that the wires extend to the front of the RJ45 plug and make good contact with the metal contacts in the RJ45 plug 13 Push back the CAT5E plug cover on the connector plug Note It is recommended th...

Page 57: ...nfidential 4 10 2 Preparing the Ethernet Cable Already Assembled To prepare the Ethernet cable already assembled 1 Release the gland cap and the gland rubber slightly 2 Insert the CAT5E cable into the...

Page 58: ...the CAT5E cable to the IP 20C HP 3 Screw the gland into the radio unit Important Note Before tightening the gland make sure the gland is even with the cover Tighten the gland gently and make sure the...

Page 59: ...to each unit The MIMO Protection signaling cables are available pre assembled from Ceragon in various lengths but users can also prepare them in the field The following sections explain how to prepar...

Page 60: ...Even for systems that use in band management initial configuration of a 4x4 MIMO and any HSB protection configuration must be performed manually using out of band management MIMO Protection signaling...

Page 61: ...dual core configuration can be considered as single core configuration hardware ready for its dual core counterpart Therefore you should follow the procedure for 2 0 SP installation if you want to ins...

Page 62: ...When fastening a waveguide to the radio or mediation device use the following torque according to frequency and screw type 4 5 GHz M6 10 Nm 6 GHz M5 10 32 3 5 Nm 7 8 11 GHz M4 8 32 2 5 Nm In addition...

Page 63: ...ibility In most cases the Diplexers unit should be attached to the antenna or mediation device first Then attach the radio unit to the Diplexers unit Figure 25 IP 20C HP Installation Radio and Diplexe...

Page 64: ...st of Items Item Description Quantity Marketing Model 1 IP 20C HP Radio Unit 1 See Section 2 4 1 Marketing Models for Radio Unit 2 IP 20C HP Diplexer Unit 1 See Section 2 4 2 Marketing Models for Dipl...

Page 65: ...plexer to the TRX using the two location pins Make sure that the hook and the carrying handle are on the same side in both the radio unit and the diplexer unit Figure 29 Figure 26 Fitting the Diplexer...

Page 66: ...Installation Guide for FibeAir IP 20C HP Page 66 of 204 Ceragon Proprietary and Confidential Figure 28 Radio and Diplexer Units Together Figure 29 Hook and Carrying Handle...

Page 67: ...unit using the eight M5 screws supplied with the radio unit First gently tighten the screws in the order shown in Figure 30 Then strongly tighten the screws in the same order Figure 30 Securing the Di...

Page 68: ...1 See Section 2 4 1 Marketing Models for Radio Unit 2 IP 20C HP Diplexer Unit 1 See Section 2 4 2 Marketing Models for Diplexer Unit 3 IP 20C HP OMT KIT 1 DXDH MD OMT ff 4 CIRC CIRC Adaptor 1 Per Ante...

Page 69: ...it with four screws Important Verify that the O ring is properly mounted between the antenna transition and the OMT 3 Connect the IP 20C HP radio dual coupler to the OMT kit using the four M8 captive...

Page 70: ...antenna vendor s documentation Note This procedure can also be used for 1 0 DP HW ready for 2 0 DP configurations List of Items Item Description Quantity Marketing Model 1 IP 20C HP Radio Unit 1 See S...

Page 71: ...w the antenna manufacturer s instructions to use the circular adaptor Remove the existing rectangular transition swap the O ring and install the circular transition instead 2 Connect the OMT kit to th...

Page 72: ...nt Adapter to the IP 20C HP OMT ports using the screws supplied with the adapter kit 4 Mount and tighten the O ring and the flexible waveguide to the adapter ports using the screws supplied with the f...

Page 73: ...gurations use 39 Nm torque For 6 11 GHz configurations use 39 Nm torque Figure 31 Remote Pole Mount Kit 6 11 GHz Figure 32 Remote Pole Mount Kit 4 5 GHz 6 Mount and tighten the IP 20C HP Remote Mount...

Page 74: ...ial 7 Mount and tighten the IP 20C HP Radio to the IP 20C HP Pole Mount using the four flat screws supplied with the IP 20C HP Radio 8 Mount and tighten both Flexible WGs with their O ring to the IP 2...

Page 75: ...for 1 0 SP HW ready for 2 0 SP configuration List of Items Item Description Quantity Marketing Model 1 IP 20C HP RADIO 1 See Section 2 4 1 Marketing Models for Radio Unit 2 IP 20C HP Diplexer Unit 1...

Page 76: ...tial Procedure 1 Adjust the twist on the Splitter Kit Perform one of the following steps according to the required polarization horizontal or vertical For horizontal polarization locate the twist with...

Page 77: ...e four M8 screws and washers Important Verify that the O ring is properly mounted between the antenna transition and the splitter 3 Connect the IP 20C HP DC radio to the splitter kit using the four M8...

Page 78: ...configurations List of Items Item Description Quantity Marketing Model 1 IP 20C HP Radio 2 See Section 2 4 1 Marketing Models for Radio Unit 2 IP 20C HP Diplexer Unit 2 See Section 2 4 2 Marketing Mod...

Page 79: ...turer s instructions to use the circular adaptor Remove the existing rectangular transition swap the O ring and install the circular transition instead 2 Connect the IP 20C HP OMT Kit to the antenna a...

Page 80: ...s and washers and tighten the screws Important Verify that the O rings are properly mounted between the OMT ports and the dual coupler 4 Mount and tighten the IP 20C HP DC radio unit to both sides of...

Page 81: ...204 Ceragon Proprietary and Confidential 5 Connect the MIMO signaling cable between the management ports of both units For additional instructions on preparing and connecting this cable refer to Prep...

Page 82: ...Section 2 4 1 Marketing Models for Radio Unit 2 IP 20C HP Diplexer Unit 2 See Section 2 4 2 Marketing Models for Diplexer Unit 3 IP 20C HP OMT KIT 1 DXDH MD OMT ff 4 IP 20C HP DUAL COUPLER KIT 1 DXDH...

Page 83: ...rior to the installation follow the antenna manufacturer s instructions to use the circular adaptor Remove the existing rectangular transition swap the O ring and install the circular transition inste...

Page 84: ...nt Adapter to the IP 20C HP OMT ports using the screws supplied with the adapter kit 4 Mount and tighten the O ring and the flexible waveguide to the adapter ports using the screws supplied with the f...

Page 85: ...the four washers and screws supplied with the IP 20C HP DC pole mount kit See Steps 5 and 6 in Section 6 5 2 0 Dual Polarization Remote Mount 6 Mount and tighten the IP 20C HP Remote Mount Adaptor pl...

Page 86: ...to the IP 20C HP Pole Mount using the four flat screws supplied with the IP 20C HP Radio 8 Mount and tighten the IP 20C HP Dual Coupler to the IP 20C HP Pole Mount using the four screws and washers th...

Page 87: ...Proprietary and Confidential 9 Mount and tighten the IP 20C HP radios on each side of the IP 20C HP Dual Coupler using the screws assembled on IP 20C HP radio Pay attention that the O rings are corre...

Page 88: ...h each Flexible Waveguide Kit to the IP 20C HP Dual Coupler antenna ports Tighten the screws and washers supplied with the Flexible Waveguide Kit 11 Connect the protection signaling cable between the...

Page 89: ...SP configurations List of Items Item Description Quantity Marketing Model 1 IP 20C HP RADIO 2 See Section 2 4 1 Marketing Models for Radio Unit 2 IP 20C HP Diplexer Unit 2 See Section 2 4 2 Marketing...

Page 90: ...ial Procedure 1 Adjust the twist on the Splitter Kit Perform one of the procedures below according to the required polarization horizontal or vertical For horizontal polarization locate the twist with...

Page 91: ...04 Ceragon Proprietary and Confidential 2 Mount the Splitter Kit on the antenna using four M8 screws and washers and tighten the screws 3 Connect the IP 20C HP Dual Coupler Kit to the Splitter Kit usi...

Page 92: ...er Kit using the supplied captive screws and washers Pay attention that the O rings are correctly mounted on the radio ports of the IP 20C HP Dual Coupler 5 Connect the protection signaling cable betw...

Page 93: ...Items Item Description Quantity Marketing Model 1 IP 20C HP RADIO 2 See Section 2 4 1 Marketing Models for Radio Unit 2 IP 20C HP Diplexer Unit 2 See Section 2 4 2 Marketing Models for Diplexer Unit...

Page 94: ...r to the installation follow the antenna manufacturer s instructions to use the circular adaptor Remove the existing rectangular transition swap the O ring and install the circular transition instead...

Page 95: ...al Coupler Kit to the OMT Kit using four M8 screws and washers and tighten the screws 4 Mount and tighten the IP 20C HP DC radio unit to both sides of the Dual Coupler Kit using the supplied captive s...

Page 96: ...ting Models for Radio Unit 2 IP 20C HP Diplexer Unit 2 See Section 2 4 2 Marketing Models for Diplexer Unit 3 IP 20C HP OMT KIT 1 DXDH MD OMT ff 4 IP 20C HP DUAL COUPLER or SPLITTER KIT 1 DXDH MD DUAL...

Page 97: ...w the antenna manufacturer s instructions to use the circular adaptor Remove the existing rectangular transition swap the O ring and install the circular transition instead 2 Connect the OMT kit to th...

Page 98: ...roprietary and Confidential 3 Mount and tighten the appropriate adapter to the IP 20C HP OMT ports using the screws supplied with the adapter kit For 6 GHz there are two adaptors Figure 35 6 GHz Mount...

Page 99: ...e adaptor Figure 37 Mounting the Single Adaptor for 7 8 10 and 11 GHz 4 Mount and tighten the O ring and the flexible waveguide to the adapter ports using the screws supplied with the flexible wavegui...

Page 100: ...HP DC pole mount to the pole using the four washers and screws supplied with the IP 20C HP DC pole mount kit 6 Mount and tighten the IP 20C HP Remote Mount Adaptor plate supplied in IP 20C HP Adaptor...

Page 101: ...n Guide for FibeAir IP 20C HP Page 101 of 204 Ceragon Proprietary and Confidential 7 Mount and tighten the IP 20C HP Radio to the IP 20C HP Pole Mount using the four flat screws supplied with the IP 2...

Page 102: ...P configurations List of Items Item Description Quantity Marketing Model 1 IP 20C HP RADIO 2 See Section 2 4 1 Marketing Models for Radio Unit 2 IP 20C HP Diplexer Unit 2 See Section 2 4 2 Marketing M...

Page 103: ...tial Procedure 1 Adjust the twist on the Splitter Kit Perform one of the procedures below according to the required polarization horizontal or vertical For horizontal polarization locate the twist wit...

Page 104: ...04 Ceragon Proprietary and Confidential 2 Mount the Dual Core Kit on the antenna using four M8 screws and washers and tighten the screws 3 Connect the IP 20C HP Dual Coupler Kit to the Splitter Kit us...

Page 105: ...Proprietary and Confidential 4 Mount and tighten the IP 20C HP DC radio unit to both sides of the Dual Coupler Kit using the supplied captive screws and washers Pay attention that the O rings are cor...

Page 106: ...antity Marketing Model 1 IP 20C HP RADIO 2 See Section 2 4 1 Marketing Models for Radio Unit 2 IP 20C HP Diplexer Unit 2 See Section 2 4 2 Marketing Models for Diplexer Unit 3 Adaptor Remote Mount Kit...

Page 107: ...e Mount Adaptor plate supplied in the IP 20C HP Adaptor Remote Mount kit to the IP 20C HP Pole Mount using the four flat screws supplied with the IP 20C HP Adaptor Remote Mount kit 2 Mount and tighten...

Page 108: ...Dual Coupler to the IP 20C HP Splitter using the four captive screws and washers that are supplied with the IP 20C HP Dual Coupler kit Make sure that the O rings are mounted on the IP 20C HP Splitter...

Page 109: ...been partially tightened repeat this process in a similar fashion with the central screws Then proceed to fully tighten all the screws in the same order Important Verify that the O rings on the Dual C...

Page 110: ...location pins are located on either the left of the upper TRX port and the right of the lower TRX port or the right of the upper TRX port and the left of the lower TRX port depending on the frequency...

Page 111: ...tions List of Items Item Description Quantity Marketing Model 1 IP 20C HP RADIO 1 See Section 2 4 1 Marketing Models for Radio Unit 2 IP 20C HP Diplexer Unit 1 See Section 2 4 2 Marketing Models for D...

Page 112: ...tial Procedure 1 Adjust the twist on the Splitter Kit Perform one of the procedures below according to the required polarization horizontal or vertical For horizontal polarization locate the twist wit...

Page 113: ...er Kit on the antenna using four M8 screws and washers and tighten the screws 3 Connect the IP 20C HP DC radio to the Splitter kit using the four M8 captive screws and washers supplied and tighten the...

Page 114: ...nfigurations List of Items Item Description Quantity Marketing Model 1 IP 20C HP RADIO 1 See Section 2 4 1 Marketing Models for Radio Unit 2 IP 20C HP Diplexer Unit 1 See Section 2 4 2 Marketing Model...

Page 115: ...P 20C HP Adaptor Remote Mount kit to the IP 20C HP Pole Mount using the four flat screws supplied with the IP 20C HP Adaptor Remote Mount kit 2 Mount and tighten the IP 20C HP Radio to the IP 20C HP P...

Page 116: ...beAir IP 20C HP Page 116 of 204 Ceragon Proprietary and Confidential 3 Mount and tighten both Flexible WGs with their O ring to the IP 20C HP Remote Mount Adaptor ports using the four screws supplied...

Page 117: ...r 2 2 SD configurations List of Items Item Description Quantity Marketing Model 1 IP 20C HP RADIO 2 See Section 2 4 1 Marketing Models for Radio Unit 2 IP 20C HP Diplexer Unit 2 See Section 2 4 2 Mark...

Page 118: ...on installation of the IP 20C OMT and radios see 2 0 Dual Polarization Direct Mount on page 68 2 Connect the source sharing cable between both EXT REF IP 20C HP radio connectors The maximum torque for...

Page 119: ...f 204 Ceragon Proprietary and Confidential 4 Connect the MIMO signaling cable between the management ports of both units For additional instructions on preparing and connecting this cable refer to Pre...

Page 120: ...eting Model 1 IP 20C HP Radios 2 See Section 2 4 1 Marketing Models for Radio Unit 2 IP 20C HP Diplexer Units 2 See Section 2 4 2 Marketing Models for Diplexer Unit 3 IP 20C HP Dual Coupler or Dual Sp...

Page 121: ...tenna and secure it with four screws Important Verify that the O ring is properly mounted between the antenna transition and the OMT Splitter OMT O Ring 2 If you are using a Splitter adjust the twist...

Page 122: ...e letter V on top 3 Connect the IP 20C HP Dual Coupler or Dual Splitter kit to the OMT Splitter using four M8 screws and washers supplied in the Dual Coupler and tighten the screws Important Verify th...

Page 123: ...r unit Smooth tin foil sheets on the side facing the waveguide interfaces Make sure they are properly placed and not bent or wrinkled It is also important to ensure that the tin foil sheets do not get...

Page 124: ...Fasten the upper right screw of the top Diplexer and then the lower left screw of the bottom Diplexer then fasten the upper left screw of the top Diplexer and then the lower right screw of the bottom...

Page 125: ...unit to the Diplexer unit using the 8 M5 captive screws supplied with the Radio kit Position the Radio unit on the Diplexer unit so that the two location pins mounted on the TRX ports of the Diplexer...

Page 126: ...ond Diplexer unit and the second Radio unit to the other side of the Dual Coupler Dual Splitter or Dual Circulator 9 Connect the protection signaling cable between the management ports of both units F...

Page 127: ...l 6 18 4 0 with Dual Circulator Direct Mount The following example illustrates a typical configuration assuming that The regulation specifies a channelization of 8 consecutive 28 38MHz channels 1 8 ch...

Page 128: ...See Section 2 4 2 Marketing Models for Diplexer Unit 3 IP 20C HP OMT Kit 1 DXDH MD OMT ff 4 Flexible Waveguide Kit 2 5 IP 20C HP Dual Circulator Splitter 1 DXDH MD DUAL CIRC ff DXDH MD DUAL SPLTR ff 6...

Page 129: ...P Adaptor Remote Mount kit See Steps 5 and 6 in Section 6 5 2 0 Dual Polarization Remote Mount 3 Mount and tighten the IP 20C HP Dual Coupler to the IP 20C HP Pole Mount using the four screws and wash...

Page 130: ...iplexer then fasten the upper left screw of the top Diplexer and then the lower right screw of the bottom Diplexer Once the outer screws have all been partially tightened repeat this process in a simi...

Page 131: ...unit to the Diplexer unit using the 8 M5 captive screws supplied with the Radio kit Position the Radio unit on the Diplexer unit so that the two location pins mounted on the TRX ports of the Diplexer...

Page 132: ...h the second Diplexer unit and the second Radio unit to the other side of the Dual Circulator Splitter 8 Connect both Flexible Waveguides and Sealing Gaskets supplied with each Flexible Waveguide Kit...

Page 133: ...tach the OMT Remote Mount Adapter to the OMT using the screws supplied with the OMT Remote Mount Adapter kit 10 Connect both Flexible Waveguides and Sealing Gaskets supplied with each Flexible Wavegui...

Page 134: ...prietary and Confidential 6 20 4 0 with Dual Circulator Remote Mount The following example illustrates a typical configuration assuming that The regulation specifies a channelization of 8 consecutive...

Page 135: ...Marketing Models for Radio Unit 2 IP 20C HP Diplexer Units 4 See Section 2 4 2 Marketing Models for Diplexer Unit 3 Dual Circulator 2 DXDH MD DUAL CIRC ff 4 IP 20C HP_MC_DUAL_CIRC_kit_xxG 1 Required...

Page 136: ...t and tighten the IP 20C HP MC Dual Cir to the IP 20C HP pillar adapter bracket using the four M8 Hex screws and washers supplied within the kit 11 GHz only 1 Mount and tighten the IP 20C HP MC extend...

Page 137: ...20C HP MC Extender using the four M8 Hex screws and washers supplied within the kit 6 11GHz 1 Mount and tighten the IP 20C HP Dual Cir to each side of the IP 20 MC Dual Circ using the four M8 Hex scre...

Page 138: ...C HP Dual Circ are well in place during the mounting 3 Mount and tighten the IP 20C HP MC Remote mount adapter to theIP 20C HP MC Dual Circ antenna ports using the four screws assembled on the IP 20C...

Page 139: ...ion Guide for FibeAir IP 20C HP Page 139 of 204 Ceragon Proprietary and Confidential 5 Mount and tighten the O ring and flexible WG to both antenna ports using the four screws supplied with the flexib...

Page 140: ...ecutive 28 30 MHz channels 1 8ch The actual channels in use are channels 1 5 4 0 Configuration Antenna Ports Low Channels Radio i e Ch1 V H High Channels Radio i e Ch5 V H 1 2 3 4 5 6 7 8 Antenna Port...

Page 141: ...to connect the two Remote Mount Adaptor ports to an antenna This chapter describes a hub site installation For standard interface antennas six feet and larger no OMT and no Circ Circ Adaptor are used...

Page 142: ...to the installation follow the antenna manufacturer s instructions to use the circular adaptor Remove the existing rectangular transition swap the O ring and install the circular transition instead 2...

Page 143: ...IP 20C HP Adaptor Remote Mount kit to the IP 20C HP Pole Mount using the four flat screws supplied with the IP 20C HP Adaptor Remote Mount kit 4 Mount and tighten the IP 20C HP to the IP 20C HP Pole...

Page 144: ...s with their O ring to the IP 20C HP Remote Mount Adaptor ports using the four screws supplied with each Flexible WG kit The following figure shows the complete installation Note This figure shows an...

Page 145: ...based branching configurations Channel Filter Based Branching Configurations Explains how to assemble channel filter based branching configurations with references to the relevant component assembly...

Page 146: ...y and Confidential Required Tools Metric offset wrench key wrench set Procedure 1 Mount and tighten the two Branching Pillars to a pole with a diameter of 114 mm using the four M10x150 screws four was...

Page 147: ...age 147 of 204 Ceragon Proprietary and Confidential 2 Mount and tighten the Branching Pole to one of the Branching Pillars using the four M10x25 screws supplied with the OCU Mounting kit Use torque of...

Page 148: ...n OCU kit 3 IP 20C HP Radio 2 4 See Section 2 4 1 Marketing Models for Radio Unit 4 Screw Socket hex head SS DIN 912 M8x25 A2 70 4 per OCU kit Included in OCU kit 5 Screw Socket hex head SS DIN 912 M8...

Page 149: ...oprietary and Confidential 4 M8x25 Screw 5 M8x30 Screw 6 Washers Plain 7 Washers Helical spring lock 8 Branching Pole Profile Required Tools Metric offset wrench key wrench set Metric Allen key set Re...

Page 150: ...to the left when facing the inside of the OCU Figure 39 With the nose of the rail protruding to the right when facing the inside of the OCU Figure 40 1 2 4 1 2 4 Figure 39 Left Rail Configuration Fig...

Page 151: ...P 20C HP Radio Attach the M5 captive screws on the radio to the OCU kit as shown in Figure 42 Partially fasten the screws without tightening them in a diagonal fashion as shown in Figure 43 Once all t...

Page 152: ...le Profile as shown in Figure 44 and Figure 45 1 Angle the nose of the OCU Rail so as to hook underneath the nose of the Branching Pole Profile Figure 44 3 8 2 Figure 44 Angling the OCU Rail Underneat...

Page 153: ...minations have been attached 2 8 5 3 1 Figure 46 Securing the OCU Radio Unit to the Branching Pole Profile Waveguide Assemblies At this point in the installation you must install all required waveguid...

Page 154: ...have been fully fastened the complete assembly is ready to be raised via a crane Make sure to loop the cable through both shackles on the OCU Rail as shown in Figure 47 You must also loop the cable th...

Page 155: ...to connect the radio ports of adjacent OCUs on the side closest to the pole mount List of Items Item Description Quantity Marketing Model 1 IP 20C HP Branching Short U Bend Kit Depends on Configurati...

Page 156: ...nd should be supplied with bushings to seal the RF 2 Short U Bends are connected between adjacent radio ports on the side closest to the Pole Mount Place the U Bend so that the embedded 8 32 socket he...

Page 157: ...s on the far side from the pole mount List of Items Item Description Quantity Marketing Model 1 IP 20C HP Branching Long U Bend Kit Depends on Configuration FXDH RM LU Bend 06 FXDH RM LU Bend 7 8 FXDH...

Page 158: ...seal the RF 2 Long U Bends are connected between adjacent radio ports on opposite sides of the Branching Pole Profile Place the U Bend so that the embedded 8 32 socket hex screws are in line with the...

Page 159: ...Washer Helical spring lock SS ANSI 8 10 8 Per Termination Kit Included in Termination Kit 4 Washer Plain SS DIN 125 A4 A5 3 A2 70 8 Per Termination Kit Included in Termination Kit 5 Sealing Gasket 1...

Page 160: ...FXDH RM MD CPLR 06 FXDH RM MD CPLR 7 8 FXDH RM MD CPLR 11 2 6 GHz 10 32 Screws 7 11 GHz 8 32 Screws 8 Per Kit Included in Splitter Coupler Kit 3 6 GHz Washer Helical spring lock SS ANSI 10 7 11GHz Was...

Page 161: ...Mount Splitter or Remote Mount Coupler is attached to the OCU using the 8 screws helical spring washers and plain washers provided with the Coupler or Splitter kit as shown in the figure below The oth...

Page 162: ...nting kit FXDH RM MOUNT kit 4 IP 20C HP OCU Kit 1 See Section 2 4 4 Marketing Models for OCU Unit 5 IP 20C HP Termination Kit 1 FXDH RM TERM 06 FXDH RM TERM 7 8 FXDH RM TERM 11 6 Flexible Waveguides 2...

Page 163: ...Connect a flexible waveguide from the lower radio port of the OCU on the side facing away from the pole to the upper radio port of the OCU on the side facing towards the pole 5 Connect a flexible wave...

Page 164: ...Unit 5 IP 20C HP Termination Kit 2 FXDH RM TERM 06 FXDH RM TERM 7 8 FXDH RM TERM 11 6 IP 20C HP OMT Kit 1 DXDH MD OMT ff 7 Flexible Waveguide Kit 2 Procedure 1 Assemble the OCU Mounting Kit See Secti...

Page 165: ...de for FibeAir IP 20C HP Page 165 of 204 Ceragon Proprietary and Confidential 5 On the side of the OCU facing away from the pole connect the flexible waveguides between the radio ports and the OMT Ver...

Page 166: ...6 IP 20C HP Branching Short U Bend Kit 2 FXDH RM U Bend 06 FXDH RM U Bend 7 8 FXDH RM U Bend 11 7 Flexible Waveguides 2 Procedure 1 Assemble the OCU Mounting Kit See Section 7 1 1 Assembling the OCU...

Page 167: ...Connect a flexible waveguide from the lower radio port of the OCU on the left to the upper radio port of the OCU on the right Connect a flexible waveguide from the upper radio port of the OCU on the...

Page 168: ...U Bend 7 8 FXDH RM U Bend 11 7 IP 20C HP OMT Kit 1 DXDH MD OMT ff 8 Flexible Waveguides 2 Procedure 1 Assemble the OCU Mounting Kit See Section 7 1 1 Assembling the OCU Mounting Kit 2 Assemble an OCU...

Page 169: ...ary and Confidential 5 On the side facing away from the pole Connect flexible waveguides from both radio ports of the OCU on the left to the OMT Connect Terminations to both radio ports of the OCU on...

Page 170: ...e 1 Part of OCU Mounting kit FXDH RM MOUNT kit 3 IP 20C HP Branching Pillar 2 Part of OCU Mounting kit FXDH RM MOUNT kit 4 IP 20C HP OCU Kit 3 See Section 2 4 4 Marketing Models for OCU Unit 5 IP 20C...

Page 171: ...ail Configuration Attach an IP 20C HP radio to each OCU and connect the radio OCU assemblies to the Branching Pole Profile as shown in the following figure See Section 7 1 2 Assembling the OCU Left Le...

Page 172: ...Connect a flexible waveguide from the lower radio port of the OCU on the left to the upper radio port of the adjacent OCU Connect a Long U Bend between the lower radio port of the middle OCU and the...

Page 173: ...nting kit FXDH RM MOUNT kit 3 IP 20C HP Branching Pillar 2 Part of OCU Mounting kit FXDH RM MOUNT kit 4 IP 20C HP OCU Kit 3 See Section 2 4 4 Marketing Models for OCU Unit 5 IP 20C HP Termination Kit...

Page 174: ...each OCU and connect the radio OCU assemblies to the Branching Pole Profile as shown in the following figure See Section 7 1 2 Assembling the OCU Left Left Right 3 On the side of the OCU facing the p...

Page 175: ...and Confidential 5 On the side facing away from the pole On the OCU to the left connect a flexible waveguide from each radio port of the OCU to the OMT Connect a Long U Bend between each set of radio...

Page 176: ...e 1 Part of OCU Mounting kit FXDH RM MOUNT kit 3 IP 20C HP Branching Pillar 2 Part of OCU Mounting kit FXDH RM MOUNT kit 4 IP 20C HP OCU Kit 4 See Section 2 4 4 Marketing Models for OCU Unit 5 IP 20C...

Page 177: ...nfiguration and two using a Right Rail Configuration Attach an IP 20C HP radio to each OCU and connect the radio OCU assemblies to the Branching Pole Profile as shown in the following figure See Secti...

Page 178: ...o the lower radio port of OCU 2 Connect a flexible waveguide from the lower radio port of OCU 1 to the antenna Connect a flexible waveguide from the lower radio port of OCU 3 to the upper radio port o...

Page 179: ...nting kit FXDH RM MOUNT kit 3 IP 20C HP Branching Pillar 2 Part of OCU Mounting kit FXDH RM MOUNT kit 4 IP 20C HP OCU Kit 4 See Section 2 4 4 Marketing Models for OCU Unit 5 IP 20C HP Termination Kit...

Page 180: ...ion Attach an IP 20C HP radio to each OCU and connect the radio OCU assemblies to the Branching Pole Profile as shown in the following figure See Section 7 1 2 Assembling the OCU Left 1 Left 3 Right 2...

Page 181: ...efer to the numbering in the figure above Connect a flexible waveguide from each of the radio ports on OCU 1 to the OMT Connect Long U Bends between the upper and lower radio ports of OCU 2 and OCU 3...

Page 182: ...or Radio Unit 2 IP 20C HP Branching Pole Profile 1 Part of OCU Mounting kit FXDH RM MOUNT kit 3 IP 20C HP Branching Pillar 2 Part of OCU Mounting kit FXDH RM MOUNT kit 4 IP 20C HP OCU Kit 2 See Sectio...

Page 183: ...t 2 Assemble two OCUs both using a Left Rail Configuration Attach an IP 20C HP radio to each OCU and connect the radio OCU assemblies to the Branching Pole Profile as shown in the following figure See...

Page 184: ...e above Connect a Coupler to the upper radio port of OCU 1 See Section 7 1 6 Assembling a Splitter or Coupler for Filter Based Branching Connect a flexible waveguide from the Coupler to the upper radi...

Page 185: ...U Kit 4 See Section 2 4 4 Marketing Models for OCU Unit 5 IP 20C HP Termination Kit 4 FXDH RM TERM 06 FXDH RM TERM 7 8 FXDH RM TERM 11 6 IP 20C HP Branching Short U Bend Kit 4 FXDH RM U Bend 06 FXDH R...

Page 186: ...eragon Proprietary and Confidential 2 Connect the OMT Kit to the antenna and secure it with four screws Verify the existence of the O ring 3 Mount and tighten the Remote Mount Adapter to the IP 20C HP...

Page 187: ...prietary and Confidential 4 Mount and tighten the O ring and the flexible waveguide to the adapter ports using the screws supplied with the flexible waveguide kit Important Verify that the O rings are...

Page 188: ...ration and two using a Right Rail Configuration Attach an IP 20C HP radio to each OCU and connect the radio OCU assemblies to the Branching Pole Profile as shown in the following figure See Section 7...

Page 189: ...ssembling a Splitter or Coupler for Filter Based Branching Connect a flexible waveguide from the upper Splitter to the upper radio port of OCU 3 Connect a flexible waveguide from the lower Splitter to...

Page 190: ...Unit 2 IP 20C HP Branching Pole Profile 1 Part of OCU Mounting kit FXDH RM MOUNT kit 3 IP 20C HP Branching Pillar 2 Part of OCU Mounting kit FXDH RM MOUNT kit 4 IP 20C HP OCU Kit 2 See Section 2 4 4 M...

Page 191: ...iguration Attach an IP 20C HP radio to each OCU and connect the radio OCU assemblies to the Branching Pole Profile as shown in the following figure See Section 7 1 2 Assembling the OCU Left 1 Left 2 3...

Page 192: ...way from the pole refer to the numbering in the figure above Connect a Coupler to each radio port of OCU 1 See Section 7 1 6 Assembling a Splitter or Coupler for Filter Based Branching Connect a flexi...

Page 193: ...e available adaptors Table 23 3rd Party Adaptors Other Vendors Antennas 6GHz 7 8GHz 10 11GHz RFU C NEC Adaptor kit PASOLINK NEO RFU C ERICSSON Adaptor kit RAU1 RFU C ERICSSON Adaptor kit RAU2 RFU C SR...

Page 194: ...s ValuLine 3 antennas 1 6ft However since there are some unique cases in which CommScope provided special antennas which are not supported by these adaptors it is recommended that you supply your Cera...

Page 195: ...is to verify correct installation and operation of the installed link and the interoperability with customer end equipment Ceragon s Acceptance and Commissioning procedure includes the following stag...

Page 196: ...OUNTING Antenna mount type Mount is of sufficient height to clear local obstructions OK Mount is safely positioned to not cause a safety hazard OK Mount is secure and perpendicular OK Mount is grounde...

Page 197: ...lts are secured using washers and lock washers as appropriate OK Flexible waveguide is secured to the pole OK 6 CAT5 Fiber Optic CABLE Overall cable length Cable type CAT5 connectors assembled properl...

Page 198: ...0 5 m recommended OK Flexible WG has no sharp bends kinks or crushed areas All bends are per manufacturer specifications OK Flexible WG point of entry to building shelter is weather proof OK Flexible...

Page 199: ...nd is safely positioned so as not to cause a safety hazard No person should be able to walk in front of or look directly into the path of the microwave radio beam Where possible the pole should be awa...

Page 200: ...the antenna after installation should be removed All other plugs should be left in position 3 ODU Outdoor Unit The ODU is grounded as per installation instructions See the third point in the Antenna...

Page 201: ...ne Interfaces Test Connect Ethernet Packet Analyzer to the GbE port Use physical loop at remote end or connect second analyzer Run Packet Loss test for at least one hour load rate as per Ceragon s spe...

Page 202: ...traps 9 4 IP 20 Commissioning Log The Commissioning Log is an integral part of the commissioning procedure and should be filled in for each installed link The Commissioning Log gathers all relevant i...

Page 203: ...Mounting losses 4 LINK PARAMETERS Site 1 Site 2 Link distance Rain zone Expected RSL dBm Expected Diversity RSL dBm RSL Main dBm RSL Diversity dBm Deviation from exp RSL 4 dB 5 COMMISSIONING TESTS Si...

Page 204: ...tallation Guide for FibeAir IP 20C HP Page 204 of 204 Ceragon Proprietary and Confidential 8 INSTALLATION INFORMATION Installed by Name Company Date Signature Commissioned by Name Company Date Signatu...