Installation Guide for FibeAir IP-20C-HP
Page 146 of 204
Ceragon Proprietary and Confidential
Required Tools
•
Metric offset wrench key wrench set
Procedure
1 Mount and tighten the two Branching Pillars to a pole with a diameter of 114
mm using the four M10x150 screws, four washers, and eight nuts supplied
with the OCU Mounting kit. Use torque of 45 Nm.