Ethernet (Ethernet 1, Ethernet 2)
Marking: X1 Ethernet1 and X3 Ethernet2
Connector Type: DIN M12 4-pole, D-coded, female
The ports support 10/100 Mbps, i.e. communication speed up to 100 Mbps.
CAN (CAN1, CAN2)
Marking: X6 CAN1 and X7 CAN2
Connector Type: DIN M12, 5-pole A-coded, female
The CAN connector follows the CANopen standard
The interface has a PCA82C251 high speed transceiver installed and follows the ISO
11898-24V standard. There is no termination in the interface; therefore, this shall be
present in the cable.
The CAN connectors can be used to supply power to external units using pin 2 and 3. The
output has a current limit that depends on the internal unit temperature. The current is
limited to 0.31A at an internal unit temperature of 70 degrees Celsius.
Protection against external voltage (up to 40V) higher than the supply voltage is provided
from a diode in series with the output. The supply voltage will be the same as the filtered
supply to the CC Pilot™ XS with an additional voltage drop over the diode in series, i.e. the
output voltage will be about 23 volts when 24 volts is supplied.
Pin Signal
1
TX+
2
RX+
3
TX-
4
RX-
CAN 1 & CAN 2
Pin
Signal
Description
1
-
No connection
2
CAN V+
8-36 V Out
3
GND
4
CAN1 H
CAN High bus line
5
CAN1 L
CAN Low bus line
Summary of Contents for CC Pilot XS All-Integrated
Page 23: ...User Manual and Reference Handbook for the CC Pilot XS 23 Display Panel Dimensions for 10 4...
Page 24: ...User Manual and Reference Handbook for the CC Pilot XS 24 Display Panel Dimensions for 6 5...
Page 48: ...User Manual and Reference Handbook for the CC Pilot XS 48...
Page 50: ...User Manual and Reference Handbook for the CC Pilot XS 50...