User Manual and Reference Handbook for the CC Pilot™ XS
46
Environmental Tolerance
Environmental Test
Standard
Comments
Vibration
IEC 60068-2-64
0,01 g
2
/Hz 5-200 Hz
1,39g (RMS) 1h
Shock
IEC 60068-2-27
5 g/30 ms ±3x3
Dry Heat
EN 60068-2-2 Bd
Operating: +65°C, 24h
Storage: +70°C, 24h
Damp Heat
EN 60068-2-30 Db
Operation: +25°C / +55
>93% RH
2*24h
Cold
EN 60068-2-1 Ad
Operating: -40°C, 24h
Storage: -40°C, 24h
Enclosure
EN 60529
IP67
EMC Directive
2004/108/EC
EN 61000-6-2:2001
EN 61000-6-4:2001
EMC Immunity,
Transient
EN 61000-4-4 (Burst)
EN 61000-4-5 (Surge)
+/- 2 kV
+/- 2 kV
EMC Immunity, ESD
EN 61000-4-2
8 kV air, 4 kV contact
EMC Immunity, RF
EN 61000-4-3
EN 61000-4-6
20 V/m, 80 MHz to 2 GHz
15 V, 15 kHz to 80 MHz
EMC Emission
EN 55022 Class A
Measured from10 m
Radiated:
30 to 230 MHz 40 dBµV/m
230 MHz to1 GHz 47 dBµV/m
Conducted:
9 kHz to150 kHz 103-83 dBµV
150 kHz to 500 kHz 79 dBµV
500 kHz to 30 MHz 73 dBµV